Lenovo 6433 Manual Do Utilizador

Página de 110
Table
 
11.
 
Abbreviated
 
list
 
of
 
POST
 
error
 
codes
 
(continued)
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Error
 
code
 
Description
 
Action
 
151
 
Real-time
 
clock
 
error.
 
1.
   
Reseat
 
the
 
battery.
 
2.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
Battery
 
b.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
162
 
Invalid
 
configuration
 
information
 
or
 
CMOS
 
random-access
 
memory
 
(RAM)
 
checksum
 
failure.
 
1.
   
Run
 
the
 
Configuration/Setup
 
Utility
 
program,
 
select
 
Load
 
Default
 
Settings
,
 
and
 
save
 
the
 
settings.
 
2.
   
Reseat
 
the
 
following
 
components:
 
a.
   
Battery
 
b.
   
Failing
 
device
 
(if
 
the
 
device
 
is
 
a
 
FRU,
 
the
 
device
 
must
 
be
 
reseated
 
by
 
a
 
trained
 
service
 
technician
 
only)
3.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
Battery
 
b.
   
Failing
 
device
 
(if
 
the
 
device
 
is
 
a
 
FRU,
 
the
 
device
 
must
 
be
 
replaced
 
by
 
a
 
trained
 
service
 
technician
 
only)
 
c.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
163
 
Time
 
of
 
day
 
not
 
set.
 
1.
   
Run
 
the
 
Configuration/Setup
 
Utility
 
program,
 
select
 
Load
 
Default
 
Settings
,
 
make
 
sure
 
that
 
the
 
date
 
and
 
time
 
are
 
correct,
 
and
 
save
 
the
 
settings.
 
2.
   
Reseat
 
the
 
battery.
 
3.
   
Clear
 
CMOS.
 
See
 
the
 
Hardware
 
Maintenance
 
Manual
 
for
 
information
 
about
 
how
 
to
 
clear
 
CMOS.
 
4.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
Battery
 
b.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
 
Chapter
 
5.
 
Solving
 
problems
 
53