IBM Type 8720 Manual Do Utilizador

Página de 180
Bus
 
error
 
messages
 
 
Note:
 
See
 
to
 
determine
 
which
 
components
 
should
 
be
 
replaced
 
by
 
a
 
field
 
service
 
technician.
 
Message
 
Action
 
Failure
 
reading
 
I2C
 
device.
 
Check
 
devices
 
on
 
bus
 
1.
 
1.
   
Reset
 
the
 
management
 
module.
 
2.
   
Reseat
 
the
 
management
 
module.
 
3.
   
Reflash
 
the
 
management
 
module.
 
4.
   
Replace
 
the
 
management
 
module.
 
Failure
 
reading
 
I2C
 
device.
 
Check
 
devices
 
on
 
bus
 
2.
 
1.
   
Reset
 
the
 
management
 
module.
 
2.
   
Reseat
 
the
 
management
 
module.
 
3.
   
Replace
 
the
 
management
 
module.
 
4.
   
Replace
 
the
 
midplane.
 
Failure
 
reading
 
I2C
 
device.
 
Check
 
devices
 
on
 
bus
 
3.
 
1.
   
Reseat
 
the
 
power
 
modules.
 
2.
   
Reseat
 
the
 
management
 
module.
 
3.
   
Replace
 
the
 
power
 
modules.
 
4.
   
Replace
 
the
 
management
 
module.
 
5.
   
Replace
 
the
 
midplane.
 
Failure
 
reading
 
I2C
 
device.
 
Check
 
devices
 
on
 
bus
 
4.
 
1.
   
Reseat
 
the
 
management
 
module.
 
2.
   
Reseat
 
the
 
cables
 
connected
 
to
 
the
 
front
 
panel
 
customer
 
interface
 
card.
 
3.
   
Reseat
 
the
 
cables
 
connected
 
to
 
the
 
rear
 
panel
 
customer
 
interface
 
card.
 
4.
   
Replace
 
the
 
front
 
panel
 
customer
 
interface
 
card.
 
5.
   
Replace
 
the
 
rear
 
panel
 
customer
 
interface
 
card.
 
6.
   
Replace
 
the
 
management
 
module.
 
7.
   
Replace
 
the
 
midplane.
 
Failure
 
reading
 
I2C
 
device.
 
Check
 
devices
 
on
 
bus
 
5.
 
1.
   
Reseat
 
the
 
switch
 
modules.
 
2.
   
Reseat
 
the
 
management
 
module.
 
3.
   
Replace
 
the
 
switch
 
modules.
 
4.
   
Replace
 
the
 
management
 
module.
 
5.
   
Replace
 
the
 
midplane.
  
Undetermined
 
problems
 
Use
 
the
 
information
 
in
 
this
 
section
 
if
 
the
 
diagnostic
 
tests
 
did
 
not
 
identify
 
the
 
failure,
 
the
 
devices
 
list
 
is
 
incorrect,
 
or
 
the
 
system
 
is
 
inoperative.
 
Notes:
  
1.
   
When
 
troubleshooting
 
a
 
BladeCenter
 
T
 
problem,
 
you
 
must
 
determine
 
if
 
the
 
problem
 
is
 
actually
 
a
 
blade
 
server
 
problem.
 
v
   
If
 
the
 
BladeCenter
 
T
 
unit
 
contains
 
more
 
then
 
one
 
blade
 
server
 
installed
 
and
 
only
 
one
 
of
 
the
 
blade
 
servers
 
exhibits
 
the
 
symptom,
 
most
 
likely
 
it
 
is
 
a
 
blade
 
server
 
problem.
 
v
   
If
 
all
 
blade
 
servers
 
exhibit
 
the
 
same
 
symptom,
 
most
 
likely
 
it
 
is
 
a
 
BladeCenter
 
T
 
unit
 
problem.
2.
   
Damaged
 
data
 
in
 
CMOS
 
can
 
cause
 
undetermined
 
problems.
 
 
104
 
BladeCenter
 
T
 
Type
 
8720
 
and
 
8730:
 
Hardware
 
Maintenance
 
Manual
 
and
 
Troubleshooting
 
Guide