IBM Type 8720 Manual Do Utilizador

Página de 180
Power
 
modules
 
AC in LED
DC out LED
DC in LED
Error LED
AC power module
DC power module
DC out LED
Error LED
  
 
Power
 
module
 
LEDs:
 
Each
 
power
 
module
 
has
 
three
 
LEDs
 
to
 
indicate
 
the
 
status
 
of
 
the
 
power
 
module.
 
v
   
AC
 
(or
 
DC)
 
in:
 
When
 
continuously
 
lit,
 
this
 
green
 
LED
 
indicates
 
that
 
the
 
input
 
power
 
source
 
is
 
working.
 
If
 
the
 
LED
 
is
 
not
 
lit,
 
it
 
indicates
 
that
 
the
 
input
 
power
 
source
 
is
 
not
 
present
 
or
 
is
 
incorrect.
 
v
   
DC
 
out:
 
When
 
continuously
 
lit,
 
this
 
green
 
LED
 
indicates
 
that
 
the
 
output
 
power
 
is
 
present.
 
If
 
the
 
LED
 
is
 
not
 
lit,
 
it
 
indicates
 
that
 
the
 
output
 
power
 
is
 
not
 
present.
 
v
   
!
 
(Error):
 
When
 
continuously
 
lit,
 
this
 
amber
 
LED
 
indicates
 
that
 
there
 
is
 
a
 
error
 
condition
 
within
 
the
 
power
 
module.
 
Table
 
3.
 
Power
 
module
 
LEDs
 
DC
 
IN
 
or
 
AC
 
IN
 
DC
 
OUT
 
!
 
(Error)
 
(amber)
 
Description
 
and
 
action
 
On
 
On
 
Off
 
The
 
power
 
module
 
is
 
on
 
and
 
operating
 
correctly.
 
On
 
Off
 
Off
 
or
 
On*
 
There
 
is
 
an
 
output
 
power
 
problem.
 
A
 
system
 
error
 
has
 
shut
 
down
 
the
 
power
 
module.
 
Actions:
 
Determine
 
the
 
cause
 
of
 
the
 
shutdown
 
using
 
the
 
diagnostics
 
and
 
replace
 
the
 
failed
 
component.
 
When
 
the
 
fault
 
has
 
been
 
cleared,
 
reset
 
the
 
power
 
module
 
in
 
one
 
of
 
the
 
following
 
ways:
 
v
   
Issue
 
a
 
power-module
 
reset
 
through
 
the
 
management
 
module.
 
v
   
Remove
 
the
 
power
 
module
 
from
 
the
 
unit
 
for
 
at
 
least
 
10
 
seconds.
If
 
the
 
problem
 
remains,
 
have
 
the
 
unit
 
serviced.
 
*Error
 
LED
 
will
 
operate
 
only
 
if
 
a
 
redundant
 
power
 
supply
 
is
 
installed.
 
 
Chapter
 
1.
 
General
 
information
 
13