Note:
  
The
 
service
 
processor,
 
management
 
module,
 
or
 
systems-management
 
function
 
must
 
monitor
 
the
 
alarm
 
reset
 
inputs
 
to
 
maintain
 
the
 
fault
 
condition
 
that
 
you
 
set
 
for
 
the
 
unit.
 
The
 
alarm
 
reset
 
inputs
 
can
 
be
 
voltages
 
in
 
excess
 
of
 
standard
 
logic
 
levels,
 
so
 
you
 
must
 
electrically
 
or
 
optically
 
isolate
 
them
 
from
 
the
 
monitoring
 
logic.
 
 
Table
 
4.
 
Alarms
 
connector
 
pinout
 
Pin
 
#
 
Description
 
I/O
 
Pin
 
#
 
Description
 
I/O
 
1
 
Minor
 
alarm
 
reset
 
+
 
I
 
9
 
Minor
 
alarm
 
normally
 
closed
 
O
 
2
 
Minor
 
alarm
 
reset
 
-
 
I
 
10
 
Minor
 
alarm
 
common
 
O
 
3
 
Major
 
alarm
 
reset
 
+
 
I
 
11
 
Major
 
alarm
 
normally
 
open
 
O
 
4
 
Major
 
alarm
 
reset
 
-
 
I
 
12
 
Major
 
alarm
 
normally
 
closed
 
O
 
5
 
Critical
 
alarm
 
normally
 
open
 
O
 
13
 
Major
 
alarm
 
common
 
O
 
6
 
Critical
 
alarm
 
normally
 
closed
 
O
 
14
 
Reserved
 
O
 
7
 
Critical
 
alarm
 
common
 
O
 
15
 
Reserved
 
O
 
8
 
Minor
 
alarm
 
normally
 
open
 
O
 
  
The
 
electrical
 
specifications
 
for
 
the
 
alarms
 
connector
 
are
 
as
 
follows:
 
   
Outputs
 
-
   
Voltage
 
range:
 
0
 
V
 
dc
 
to
 
-100
 
V
 
dc
 
(maximum
 
current
 
0.3
 
A
 
at
 
100
 
V
 
dc)
 
-
   
Current
 
range:
 
0
 
A
 
to
 
1
 
A
 
(maximum
 
voltage
 
30
 
V
 
dc
 
at
 
1
 
A)
 
-
   
Worst-case
 
VA:
 
1
 
A
 
at
 
-30
 
V
 
dc
 
(30
 
VA
 
maximum)
 
indefinitely
   
Inputs
 
-
   
Voltage
 
range:
 
0
 
V
 
dc
 
to
 
-100
 
V
 
dc
 
(including
 
transients)
 
-
   
Differential
 
input
 
voltage:
 
3
 
V
 
dc
 
to
 
72
 
V
 
dc
   
Reset
 
input
 
activation
 
Pulse
 
width:
 
200
 
ms
 
(minimum)
 
to
 
300
 
ms
I/O
 
modules
 
You
 
can
 
install
 
a
 
maximum
 
of
 
four
 
I/O
 
modules
 
at
 
the
 
rear
 
of
 
the
 
system
 
(a
 
maximum
 
of
 
four
 
Gbit
 
Ethernet
 
switches,
 
or
 
a
 
maximum
 
of
 
two
 
Gbit
 
Ethernet
 
switches
 
and
 
two
 
Fibre
 
Channel
 
switches).
 
The
 
minimum
 
system
 
configuration
 
requires
 
one
 
Gbit
 
Ethernet
 
switch
 
or
 
pass-thru
 
module.
 
The
 
I/O
 
switch
 
modules
 
provide
 
high-performance
 
connectivity
 
between
 
the
 
blade
 
servers.
 
See
 
the
 
documentation
 
that
 
comes
 
with
 
each
 
I/O
 
module
 
for
 
a
 
description
 
of
 
the
 
LEDs
 
and
 
connectors
 
on
 
the
 
I/O
 
module.
 
BladeCenter
 
T
 
unit
 
power,
 
controls,
 
and
 
indicators
 
This
 
section
 
describes
 
the
 
controls
 
and
 
light-emitting
 
diodes
 
(LEDs)
 
and
 
how
 
to
 
start
 
and
 
shut
 
down
 
the
 
BladeCenter
 
T
 
unit.
 
Starting
 
the
 
BladeCenter
 
T
 
unit
 
Complete
 
the
 
following
 
steps
 
to
 
start
 
the
 
BladeCenter
 
T
 
unit:
 
1.
   
Read
 
the
 
information
 
in
 
 
Chapter
 
1.
 
General
 
information
 
19