IBM Type 8720 Manual Do Utilizador

Página de 180
must
 
be
 
installed
 
in
 
the
 
BladeCenter
 
T
 
unit
 
in
 
I/O-module
 
bay
 
1
 
or
 
2,
 
or
 
both,
 
before
 
the
 
integrated
 
Ethernet
 
controllers
 
on
 
each
 
blade
 
server
 
system
 
board
 
can
 
be
 
used.
 
The
 
Ethernet
 
controllers
 
are
 
integrated
 
on
 
each
 
blade
 
server
 
system
 
board.
 
The
 
Ethernet
 
controllers
 
provide
 
1-Gbps
 
full-duplex
 
capability
 
only,
 
which
 
enables
 
simultaneous
 
transmission
 
and
 
reception
 
of
 
data
 
to
 
the
 
external
 
ports
 
on
 
the
 
Ethernet
 
switches.
 
You
 
do
 
not
 
need
 
to
 
set
 
any
 
jumpers
 
or
 
configure
 
the
 
controller
 
for
 
the
 
blade
 
server
 
operating
 
system.
 
However,
 
you
 
must
 
install
 
a
 
device
 
driver
 
on
 
the
 
blade
 
server
 
to
 
enable
 
the
 
blade
 
server
 
operating
 
system
 
to
 
address
 
the
 
Ethernet
 
controller.
 
For
 
blade
 
server
 
device
 
drivers
 
and
 
information
 
about
 
configuring
 
the
 
Ethernet
 
controllers,
 
see
 
the
 
Ethernet
 
software
 
CD
 
that
 
comes
 
with
 
your
 
blade
 
server.
 
BladeCenter
 
T
 
networking
 
guidelines
 
Your
 
networking
 
administrator
 
should
 
assist
 
in
 
the
 
configuration
 
of
 
the
 
network
 
infrastructure
 
before
 
you
 
connect
 
the
 
BladeCenter
 
T
 
unit
 
to
 
a
 
LAN
 
switch
 
or
 
similar
 
network
 
device.
 
This
 
section
 
provides
 
additional
 
guidelines
 
that
 
might
 
be
 
useful
 
in
 
setting
 
up
 
your
 
system.
 
A
 
BladeCenter
 
T
 
unit
 
with
 
two
 
Ethernet
 
switch
 
modules
 
and
 
one
 
management
 
module
 
has
 
the
 
internal
 
configuration
 
that
 
is
 
shown
 
in
 
the
 
following
 
illustration:
 
MAC
1a
1b
2a
2b
3a
3b
4a
4b
5a
5b
6a
6b
7a
7b
8a
8b
1
2
3
4
5
6
7
8
Switch A
Mgmt
Mod
Switch B
100 Mbps links
10/100 Mbps
1 Gbps or
100 Mbps links
1 Gbps links
1 Gbps links
Note: 2nd switch module is optional
  
 
Each
 
blade
 
server
 
has
 
two
 
independent
 
Ethernet
 
controllers,
 
each
 
with
 
its
 
own
 
MAC
 
address
 
and
 
a
 
dedicated
 
1
 
Gbps
 
link
 
to
 
one
 
of
 
the
 
switch
 
modules
 
in
 
I/O
 
module
 
bays
 
1
 
and
 
2
 
(controller
 
1
 
to
 
switch
 
A
 
and
 
controller
 
2
 
to
 
switch
 
B
 
in
 
the
 
illustration).
 
In
 
this
 
configuration
 
(the
 
default),
 
the
 
blade
 
servers
 
share
 
access
 
to
 
four
 
external
 
ports
 
on
 
each
 
switch.
 
There
 
is
 
no
 
internal
 
data
 
path
 
between
 
the
 
two
 
switches
 
within
 
the
 
BladeCenter
 
T
 
unit;
 
an
 
external
 
network
 
device
 
is
 
required
 
for
 
data
 
packets
 
to
 
flow
 
from
 
one
 
internal
 
switch
 
to
 
the
 
other.
 
The
 
management
 
module
 
has
 
a
 
separate
 
internal
 
100
 
Mbps
 
link
 
to
 
each
 
switch.
 
These
 
links
 
are
 
for
 
internal
 
management
 
and
 
control
 
only.
 
No
 
data
 
packets
 
are
 
allowed
 
to
 
flow
 
from
 
application
 
programs
 
on
 
the
 
blade
 
servers
 
to
 
the
 
management
 
module
 
over
 
this
 
path.
 
A
 
separate,
 
nonswitched
 
path
 
(not
 
shown)
 
is
 
used
 
for
 
communication
 
between
 
the
 
management
 
module
 
and
 
a
 
service
 
processor
 
on
 
each
 
blade
 
server.
 
 
Chapter
 
2.
 
Configuring
 
the
 
BladeCenter
 
T
 
unit
 
31