Chapter
 
6.
 
Symptom-to-FRU
 
index
 
This
 
index
 
supports
 
the
 
Eserver
 
BladeCenter
 
T
 
Type
 
8720
 
and
 
8730
 
systems.
 
Notes:
  
1.
   
Check
 
the
 
configuration
 
before
 
you
 
replace
 
a
 
FRU.
 
Configuration
 
problems
 
can
 
cause
 
false
 
errors
 
and
 
symptoms.
 
2.
   
For
 
IBM
 
devices
 
not
 
supported
 
by
 
this
 
index,
 
refer
 
to
 
the
 
manual
 
for
 
that
 
device.
 
3.
   
A
 
removed
 
hot-swap
 
module
 
or
 
drive
 
must
 
be
 
replaced
 
within
 
one
 
minute
 
of
 
removal.
 
4.
   
A
 
removed
 
hot-swap
 
blade
 
must
 
be
 
replaced
 
within
 
20
 
minutes
 
of
 
removal.
 
The
 
symptom-to-FRU
 
index
 
lists
 
symptoms,
 
errors,
 
and
 
the
 
possible
 
causes.
 
The
 
most
 
likely
 
cause
 
is
 
listed
 
first.
 
Use
 
this
 
symptom-to-FRU
 
index
 
to
 
help
 
you
 
decide
 
which
 
FRUs
 
to
 
have
 
available
 
when
 
servicing
 
the
 
system.
 
The
 
left-hand
 
column
 
of
 
the
 
tables
 
in
 
this
 
index
 
lists
 
error
 
codes
 
or
 
messages,
 
and
 
the
 
right-hand
 
column
 
lists
 
one
 
or
 
more
 
suggested
 
actions
 
or
 
FRUs
 
to
 
replace.
 
Note:
  
In
 
tables
 
with
 
more
 
than
 
two
 
columns,
 
multiple
 
columns
 
are
 
required
 
to
 
describe
 
the
 
error
 
symptoms.
 
Take
 
the
 
action
 
or
 
replace
 
the
 
FRU
 
suggested
 
first
 
in
 
the
 
list
 
of
 
the
 
right-hand
 
column,
 
then
 
try
 
the
 
server
 
again
 
to
 
see
 
if
 
the
 
problem
 
has
 
been
 
corrected
 
before
 
taking
 
further
 
action.
 
Note:
  
Try
 
reseating
 
a
 
suspected
 
component
 
or
 
reconnecting
 
a
 
cable
 
before
 
replacing
 
the
 
component.
 
Error
 
symptoms
 
You
 
can
 
use
 
the
 
following
 
information
 
to
 
find
 
solutions
 
to
 
problems
 
that
 
have
 
definite
 
symptoms.
 
 
Attention:
  
If
 
diagnostic
 
error
 
messages
 
appear
 
that
 
are
 
not
 
listed
 
in
 
the
 
following
 
tables,
 
make
 
sure
 
that
 
your
 
BladeCenter
 
T
 
unit
 
has
 
the
 
latest
 
level
 
of
 
firmware
 
code
 
installed.
 
If
 
you
 
have
 
just
 
added
 
a
 
new
 
option
 
and
 
your
 
system
 
is
 
not
 
working,
 
complete
 
the
 
following
 
procedure
 
before
 
using
 
the
 
troubleshooting
 
charts:
 
1.
   
Remove
 
the
 
option
 
that
 
you
 
just
 
added.
 
2.
   
Run
 
the
 
diagnostic
 
tests
 
to
 
determine
 
if
 
your
 
system
 
is
 
running
 
correctly.
 
3.
   
Reinstall
 
the
 
new
 
device.
 
©
 
Copyright
 
IBM
 
Corp.
 
2004
 
89