IBM 8682 Manual Do Utilizador

Página de 174
Message
Action
Power Supply
X
Temperature Fault
(level-critical; power supply
x
had over temperature
condition)
1. Ensure system is being properly cooled; see
2. Replace Power Supply
X
System over temperature for CPU
X
(level-warning; CPU
X
reporting over temperature
condition)
1. Ensure system is being properly cooled; see
2. Replace system board.
System under recommended CPU
X
temperature
(level-warning; system reporting under temperature
condition for CPU
X
)
1. Ambient temperature must be within normal
operating specifications; (see “Features and
specifications” on page 3).
System over recommended ambient temperature
(level-warning; ambient temperature too warm for safe
system operation)
1. Ambient temperature must be within normal
operating specifications; (see “Features and
specifications” on page 3).
Fan error messages
Message
Action
Fan
X
fault
(level-critical; fan
X
beyond recommended RPM
range)
1. Check connections to fan
X
2. Replace fan
X
Power error messages
Message
Action
Power supply
X
DC good fault
(level-critical; power good signal not detected for power
supply
X
)
1. Replace power supply
X
Power supply
X
fan fault
(level-critical; fan fault in power supply
X
)
1. Replace power supply
X
Power supply
X
fault
(level-critical; overcurrent condition exists)
Power supply
X
12V fault
(level-critical; overcurrent condition detected)
Power supply
X
3.3V fault
(level-critical; 3.3V power supply
X
had an error)
Power supply
X
5V fault
(level-critical; 5V power supply
X
had an error)
Power supply current exceeded max spec value
(level-critical; current draw in system is over allowance for
a single supply)
Symptom-to-FRU index