If you want to remove an HDD module that is not defective, the drive must 
be first set to "Offline" via the software (RAID controller configuration 
software).
Ê
Unlock the HDD module as described in section 
Ê
Pull the HDD module out a few centimeters.
Ê
Wait for at least 60 seconds. 
I
This period is necessary for the RAID controller to recognize that an 
HDD module has been removed and for the hard disk drive to come 
to a stop.
Ê
Pull the HDD module out completely.
Ê
Install the new HDD module, as described in 
V
CAUTION!
If you have removed an HDD module and do not install a new one in 
its place, put the dummy module back in its place for cooling, to 
comply with EMC regulations (regulations regarding electromagnetic 
compatibility), and for protection against fire. Ensure that the dummy 