– Connection Blade 8Gb FC Pass Thru18/18
– 18 internal 8-Gbit ports to the server blades
– 18 external ports through 8-Gb SFP+ modules or 4-Gb SFP modules
– 18 external ports through 8-Gb SFP+ modules or 4-Gb SFP modules
I
Fibre Channel connection blades can only be installed in slots CB3/4
(fabric 3)and only support server blades that are fitted with a Fibre
Channel mezzanine card.
(fabric 3)and only support server blades that are fitted with a Fibre
Channel mezzanine card.
●
Infiniband connection blade
– Connection Blade Infiniband Switch 40 Gb 18/18
– 18 internal 40-Gbit Infiniband ports to the server blades
– 18 external 40-Gbit Infiniband connections through QSFP modules
– 18 external 40-Gbit Infiniband connections through QSFP modules
I
Infiniband connection blades can only be used in the slots CB 3/4,
see
see
. They only support
server blades that are fitted with an Infiniband mezzanine card.
The connection blades support hot-swapping. By installing two connection
blades in two adjacent slots (not possible with Infiniband connection blades),
you can provide redundant network connections for the server blades (for
details, see section
blades in two adjacent slots (not possible with Infiniband connection blades),
you can provide redundant network connections for the server blades (for
details, see section
Management blade
The system unit has slots for two redundant, hot-swap management blades with
an integrated management solution for complete remote administration of the
system. The base configuration of the system unit contains one management
blade (for details, see section
an integrated management solution for complete remote administration of the
system. The base configuration of the system unit contains one management
blade (for details, see section
).
Power supply
The system unit has four installation bays for hot-plug power supply units which
automatically set themselves to a voltage in the range of 100 - 240 V. The base
configuration includes one power supply unit. As an option, you can set up a
redundant power supply with up to three additional power supply units. If a
power supply unit fails, the redundant configuration assures continued
operation. The defective power supply unit can be replaced during operation
(for further details see section
automatically set themselves to a voltage in the range of 100 - 240 V. The base
configuration includes one power supply unit. As an option, you can set up a
redundant power supply with up to three additional power supply units. If a
power supply unit fails, the redundant configuration assures continued
operation. The defective power supply unit can be replaced during operation
(for further details see section
).