Fujitsu RX200 S2 Manual Do Utilizador

Página de 307
259
PRIMERGY RX200 S2 User’s Guide    
9
O
p
eration
 a
nd 
Mainten
ance
■ Server Management Tools Error Messages
Error messages may appear while executing Server Management Tools. Perform the corresponding 
resolution listed in the table. If messages other than the following are displayed, contact an office listed 
in the "Contact Information" of the "Start Guide".
table: List of Server Management Tools Error Messages
Message
Description
Write protect error writing drive A.
 
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the 
write-protect, and then press the [R] key.
Not ready writing drive A.
 
Abort, Retry, Fail?
The floppy disk is not inserted into the floppy disk 
drive. Insert the proper floppy disk ("Server 
Management Tools" disk), and then press the [R] key.
ERROR:Fail to create data file.
The following are possible causes. Check the floppy 
disk status again.
• The floppy disk is not inserted into the floppy disk 
drive. Insert the proper floppy disk, and then retry.
• The floppy disk is write-protected. Disable the 
write-protect and retry.
• The floppy disk contains abnormal contents. Create 
the "Server Management Tools" disk again. If this 
occurred while recovering BIOS information, 
configure the information using the BIOS Setup 
Utility. Then store the BIOS information.
ERROR:Fail to write 1st CMOS data into data file. nn
ERROR:Fail to write 2nd CMOS data into data file. nn
ERROR:Fail to write ESCD data into the data file. nn
ERROR:Fail to write SEEPROM data into the data file. 
nn
ERROR:Fail to open data file.
The file for recovering the BIOS information does not 
exist on this floppy disk. Insert the floppy disk on 
which the BIOS information was stored, and then retry.
ERROR:Fail to write 1st CMOS data into system. nn
The following are possible causes. Check the floppy 
disk status again.
• The floppy disk is not inserted into the floppy disk 
drive. Insert the proper floppy disk, and then retry.
• A different model or an unsupported version of 
BIOS information. Insert the proper floppy disk, and 
then retry.
• The floppy disk contains abnormal contents. Create 
the "Server Management Tools" disk again. If this 
occurred while recovering BIOS information, 
configure the information using the BIOS Setup 
Utility. Then store the BIOS information.
ERROR:Fail to write 2nd CMOS data into system file. 
nn
ERROR:Fail to write ESCD data into system file. nn
ERROR:Fail to write SEEPROM data into system. nn
Other messages
Contact an office listed in the "Contact Information" of 