Lucent Technologies 555-233-115 Manual Do Utilizador

Página de 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-32
Standard Reliability 
5
Figure 5-8.
Collocated Fiber Optic Connections EPN1 to EPN2
For Either One or Two Fiber-Remoted Expansion Port Networks
1. At control carrier A of PPN cabinet 1. See 
 through 
.
Install a lightwave transceiver on the cable connector at slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a 
300A Lightwave Transceiver
Connect a fiber optic cable to the transceiver just installed.
Route the cable to the cable tray and down, out of the cabinet, 
through the cable manager to the PDS cross-connect facility.
Connect the fiber cable to the lightguide interconnect unit provided.
Carefully attach the cable (with cable ties) to the wall of the cable 
tray at the built-in cable tie positions.
2. Behind control carrier A of EPN cabinet 2:
Install a lightwave transceiver on cable connector at slot 2A01.
NOTE:
Attenuators may be required for single mode fiber using a 
300A Lightwave Transceiver
Connect a fiber optic cable to the transceiver just installed.
Figure Notes
1. Lightwave Transceiver
2. To PPN Carrier A Slot 2A02
3. To EPN 1 Carrier A Slot 3A02
4. Fiber Optic Cable
5. TX Connector
6. RX Connector
cydff05 CJL 103196
RX TX
2
2
1
1