Lucent Technologies 555-233-115 Manual Do Utilizador

Página de 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-136
Add MCC Port Carriers 
6
Figure 6-52.
TDM/LAN Bus Connections for Standard Reliability R8r PPN
NOTE:
On port carrier J58890BB-1, connect the TDM cable or TDM terminator to 
slot 02. On port carriers J58890BB-2 and J58890BB-3, connect the TMD 
cables or TDM terminator to slot 01. If the port carrier has J58890BB-1 and 
J58890BB-2 stencilled on it, treat it as a J58890BB-1.
Figure Notes
1. Port Carrier (“C” Position)
2. ZAHF4 TDM/LAN Terminator
3. TDM/LAN Cable (WP91716L6)
4. Process Carrier (“A” Position)
5. Port Carrier (“D” Position)
6. Port Carrier (“E” Position)
7. Slot 21
8. Slot 00
9. TDM/LAN Cable (WP91716L7)
10. Port Carrier (“B” Position)
11. Slot TDM/LAN2 (20)
cadf052 KLC 102297
1
2
2
3
3
4
5
6
7
7
7
7
7
8
9
10
3