Lucent Technologies 555-233-115 Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory
1-21
Upgrade the software and hardware
1
Release MMI (H/C only)
1. Type release board
cabinet carrier slot and press
Enter
to release the
circuit packs, which were busied out earlier.
Resolve Alarms
1. Type display alarms and press
Enter
to examine the alarm log. Resolve
any alarms that may exist using
DEFINITY Enterprise Communications
Server Release 8 Maintenance for R8r.
Check Link Status
1. Type display communication-interface links and press
Enter
. Compare it
with the earlier status.
2. Type status link
number and press
Enter
. Repeat this step for each link.
Enable Scheduled Maintenance
1. Type change system-parameters maintenance and press
Enter
.
2. Type the appropriate time in the
Start
field to enable scheduled daily
maintenance. Make sure the
Save Translation
field is set to daily.
Enable Customer Options and Alarm Origination
to INADS
to INADS
1. Get the DOSS order number of the upgrade from the project manager and
ask the regional Customer Software Administration to complete the steps
in the shaded box. See
in the shaded box. See
for telephone numbers.
NOTE:
As part of the system registration process, the INADS Database
Administrator enables Alarm Origination and customer options.
Administrator enables Alarm Origination and customer options.
2. When administration is completed, log in as craft at the
Login:
prompt.