Lucent Technologies 555-233-115 Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-15
Standard Reliability
5
Standard Reliability
Required Hardware
The equipment in
a claim for missing equipment, as part of the Streamlined Implementation
process, call 1-800-772-5409, or the number provided by your Lucent
Technologies representative.
process, call 1-800-772-5409, or the number provided by your Lucent
Technologies representative.
Table 5-6.
Required Hardware
Equipment
Description
Quantity
PEC 6300-05X
Processor Port Network
1
J58890AF-1
Expansion Control Carrier
1
106647985
TN775B Maintenance
1
103557294
or
103281788
or
103281788
TN776 Expansion Interface
TN570 Expansion Interface
2 or 6
1
2 or 6
1,2
1.
Depending on the number of Release 8 EPNs. Two are required for a standard
reliability system with 2 port networks; 6 with 3 port networks. Either 1 or 4 Expansion
Interfaces (EIs) are shipped loose with the EPN equipment. The factory has installed
either 1 or 2 EIs in the new PPN.
reliability system with 2 port networks; 6 with 3 port networks. Either 1 or 4 Expansion
Interfaces (EIs) are shipped loose with the EPN equipment. The factory has installed
either 1 or 2 EIs in the new PPN.
2.
Required port network interfaces in a Release 8 system with the optional packet bus.
407439975
20-Foot Multi-mode Fiber Optic Cable
1 or 3
3
3.
Depending on the number of DEFINITY ECS Release 8 EPNs. Two or 6 are required
if the PPN and EPN(s) are remotely located. Assuming acceptable lengths, the fiber
that previously connected an upgraded G2 universal module (not a traditional
module) to the G2 TMS has the correct transceiver connectors and can be reused.
if the PPN and EPN(s) are remotely located. Assuming acceptable lengths, the fiber
that previously connected an upgraded G2 universal module (not a traditional
module) to the G2 TMS has the correct transceiver connectors and can be reused.
106455348
or
106455363
or
106455363
9823A Lightwave Transceiver
9823B Lightwave Transceiver
2 or 6
4
2 or 6
5
4.
One pair for each fiber connection. For each connection, either 1 lightwave
transceiver is installed in an EPN and 1 in the PPN. A transceiver can be reused from
each upgraded G2 universal module. Additional transceivers, ordered separately,
are also shipped loose with the EPN equipment.
transceiver is installed in an EPN and 1 in the PPN. A transceiver can be reused from
each upgraded G2 universal module. Additional transceivers, ordered separately,
are also shipped loose with the EPN equipment.