Lucent Technologies 555-233-115 Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-19
Upgrade the software and hardware
2
8. Type standard or daylight savings in the
Type
field, according to the
current time in the local time zone. For example, if currently on standard
time, type standard.
time, type standard.
9. Type the rule number in the
Daylight Savings Rule
field.
10. When all the information is correct, press
Enter
.
11. Type display time
and press
Enter
to verify date and time data.
Set Core Dump Vector
1. Type set vector f spe-maint and press
Enter
to set the core dump vector to
perform a core dump on any system restart.
Enable TTI
NOTE:
Do this step only if the TTI is disabled and you want it enabled.
1. Type change system-parameters features and press
Enter
to change the
TTI field back to its value before the upgrade.
Release MMI (H/C only)
1. Type release board
cabinet carrier slot and press
Enter
to release the
circuit packs, which were busied out earlier.
Resolve Alarms
1. Type display alarms and press
Enter
to examine the alarm log. Resolve
any alarms that may exist using
DEFINITY Enterprise Communications
Server Release 8 Maintenance for R8r.
Check Link Status
1. Type display communication-interface links and press
Enter
. Compare it
with the earlier status.
2. Type status link
number and press
Enter
. Repeat this step for each link.
Enable Scheduled Maintenance
1. Type change system-parameters maintenance and press
Enter
.
2. Type the appropriate time in the
Start
field to enable scheduled daily
maintenance. Make sure the
Save Translation
field is set to daily.