How Drop and Insert works
141
Access Server Administrators’ Reference Guide 
10 • Drop and Insert
Figure 58. Drop and insert diagram
Note
This functionality can only be done on robbed bit lines. You can not per-
form drop and insert on a PRI line.
Using Drop and Insert
1. Configure each WAN port doing drop and insert. Links 1 and 2 perform drop and insert together. Links 3 
and 4 perform drop and insert together.
The line type/coding for all of the lines can be either D4/AMI or ESF/B8ZS
WAN A can have the following types of line signalling:
EMWinkStart
GroundStart
LoopStart
EMImmediate
WAN B and x on PBX must be configured identically.
WAN B can have the following types of line signalling:
EMWinkStart
EMImmediateStart
2. Set the Desired Function for each channel on WAN A and B to dropInsert(7) (using channel assignment 
under the T1/E1 link that is going to be performing drop and insert). The channels on WAN A selected 
for drop and insert must match the channels on WAN B selected for drop and insert. 
Note
We do not send digits with the EMWinkStart signalling. What this means is 
that you can not direct the inbound call to a specific extension on the PBX.