Citrix Systems 9.3 Manual Do Utilizador

Página de 110
Figure 1-13. 
Removing the Existing DC Power Supply
2. Carefully remove the new power supply from its box.
3. On the back of the appliance, align the power supply with the power supply slot.
4. Insert the power supply into the slot while pressing the lever towards the handle.
Apply firm pressure to insert the power supply firmly into the slot.
Figure 1-14. 
Inserting the Replacement DC Power Supply
5. When the power supply is completely inserted into its slot, release the lever.
6. Connect the power supply to a power source. If connecting all power supplies, plug
separate power cords into the power supplies and connect them to separate wall
sockets.
Note: NetScaler appliances emit a high-pitched alert if one power supply fails or if you
connect only one power cable to an appliance in which two power supplies are
installed. To silence the alarm, press the small red button on the back panel of the
appliance. The disable alarm button is functional only when the appliance has two
power supplies.
CompactFlash Card
The NetScaler software is stored on either the solid-state drive or the CompactFlash
card. The following MPX platforms store the NetScaler software on the CompactFlash
card:
w
Citrix NetScaler MPX 5500
w
Citrix NetScaler MPX 7500 and MPX 9500
w
Citrix NetScaler MPX 9700, MPX 10500, MPX 12500, and MPX 15500
w
Citrix NetScaler MPX 15000
Chapter 1
 Introduction to the Hardware Platforms
30