Tripp Lite ULTRABLOK Manual Do Utilizador

Página de 12
3
ISOBLOK
ISOFAX
ULTRABLOK
Outlets:
2 x NEMA 5-15R
2 x NEMA 5-15R
2 x NEMA 5-15R
Dimensions (H x W x D):
4 x 2½ x 2½"
5 x 2½ x 2½"
4 x 2½ x 2½"
ULTRACOAX
ULTRACOPY
ULTRAFAX
Outlets:
2 x NEMA 5-15R
2 x NEMA 5-20R
2 x NEMA 5-15R
Dimensions (H x W x D):
4 x 2½ x 2½"
4 x 2½ x 2½"
4 x 2½ x 2½"
ALL MODELS:
• UL 1283 Listed (noise reduction)
• ULTRA: UL 1449, 1998 rev. Listed (330V let-through)
• ISO: UL 1449, 1998 rev. Listed (330V let-through H-N, 400V let-through H-G & N-G)
Rated Input Voltage:
105 to 132V AC; 60 Hz; (120V AC nominal)
Energy Absorption:
600 joules
Surge/Spike Protection:
48,000 amps
High Frequency Noise Suppression:
> 20db @ 50Khz
> 40db @ 500Khz
> 75db @ 1Mhz
> 30db @ 6-1000Mhz
Transient Response Time:
Instantaneous*
* Transient amplitude reduction occurs faster than the clamp response of the varistors because of the high rejection
rate of the ISOBAR filter networks.
COAXIAL CABLE SPIKE PROTECTION (ULTRACOAX MODEL ONLY):
Peak Pulse Power Dissipation:
1500 watts
Energy Absorption:
7 joules
Clamping Voltage:
± 27V
Insertion  Loss:
Less than 3 db
Circuit Breaker:
Fast-acting  fuse
Input/Output  Connectors:
Female 'F' connectors
TELEPHONE LINE SPIKE PROTECTION (ISOFAX AND ULTRAFAX MODELS ONLY):
• UL 497A Listed (secondary communications protection)
Peak Transient Input Voltage:
6Kv, 10 microseconds
Energy Absorption:
140 joules
Response Time:
Less than 5 nanoseconds
Clamping Voltage:
200V peak, ±10%
EMI Noise Reduction:
Up to 27 db
Input/Output  Connectors:
ULTRAFAX features female RJ11 jacks; 2-wire, single line protection
ISOFAX features female RJ11/45 jacks; 4-wire, 2-line protection
CONSUMER INFORMATION AND FCC REQUIREMENTS
(FOR ISOFAX AND ULTRAFAX MODELS IN THE U.S. ONLY)
1. This equipment complies with Part 68 of the FCC rules. On the top or bottom of this equipment is a label that contains, among other
information, the FCC registration number for this equipment. If requested, provide this information to your telephone company.
2. If your Fax/Modem Protector causes harm to the telephone network, the Telephone Company may temporarily discontinue your service.
If possible, they will notify you in advance. If advance notice isn't practical, you will be notified as soon as possible. You will be advised of
your right to file a complaint with the FCC.
3. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper operation
of your equipment. If they do, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.
4. If you experience trouble with this equipment, Fax/Modem Protector, please contact Tripp Lite Customer Support, 1111 W. 35th Street,
Chicago, Illinois 60609; Phone (773) 869-1234 for repair/warranty information. The telephone company may ask you to disconnect this
equipment from the network until the problem has been corrected or you are sure that the equipment is not malfunctioning. There are no
repairs that can be made by the customer to the Fax/Modem Protector.
5. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs.
(Contact your state public utility commission or corporation commission for information.)
Specifications
9906059 Direct Plug-In Isobar Owner's Manual FINAL.p65
8/25/00, 10:58 AM
3