Excell Precision SP151 Manual Do Utilizador

Página de 10
 
 
ZSME000000016 
EXCELL PRECISION CO., LTD
 
SP151 Weighing System Surge Protector 
 
The high performance surge protector device applies to 4- or 6-wire load cell 
weighing systems or other related applications. 
 
1.  General 
SP151 Surge Protector is designed for accessing direct into the cabling of the weighing 
system, in order to prevent the load cells and other sensitive electronic components from 
damage by a near surge strike or power failure. Surge protector works at the local only, 
therefore, SP151 devices should be installed on both ends of circuitry loop. 
 
A complete system protection requires additional surge protection device(s) to ensure 
that other items, such as AC power, external printers, mainframes, and telephone and so 
on. 
 
2. Installation 
The following recommendation is only as a reference. Take into account of local conditions, 
the installation should always be carried out by professionals. 
 
2.1 Siting 
SP151 should be set within 3m from the load cells or systems to be protected. For the 
maximum degree of protection, SP151 should be used at both ends concurrently of the 
interconnected cables. In general, install a protective device between the junction box and 
load cells set (Figure 1). Some systems specify load cell individual cable(s), protections are 
needed for every load cell (Figure 2). Within the weighbridge, the SP151 should be set 
close to the indication systems, the interconnecting cables must be separated by at 
least 50mm from other irrelevant cables.