UPC/EAN Version
Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C. or an EAN linear compo-
nent.  (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.)  Default = UPC/EAN Ver-
sion Off.
Note: If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from 
the GS1 DataBar code.  See 
 (page 7-20) for further information.
GS1 Composite Code Message Length
Scan the bar codes below to change the message length.  Refer to 
 (page 7-1) for additional 
information.  Minimum and Maximum lengths = 1-2435.   Minimum Default = 1, Maximum Default = 2435.
GS1 Emulation
The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent 
GS1-128 or GS1 DataBar  symbol.  GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and 
GS1-128 DataBar and GS1 Composites.  (Any application that accepts GS1 data can be simplified since it only needs to recog-
nize one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits.  If the AIM ID 
is enabled, the value will be the GS1-128 AIM ID, ]C1 (see 
If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits.  If the AIM 
ID is enabled, the value will be the GS1-DataBar AIM ID, ]em (see 
If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and UPC-E expansion is controlled by the 
 (page 7-20) setting.  If the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see 
If EAN8 to EAN13 Conversion is scanned, all EAN8 bar codes are converted to EAN13 format.  
Default = GS1 Emulation Off.
UPC/EAN Version On
*  UPC/EAN Version Off
Minimum Message Length
Maximum  Message Length
GS1-128 Emulation