Canon GM-1000 Manual Do Utilizador

Página de 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
73
A response is necessary after confirming the error 
details with the control software, or RS-232C 
command ID = 15 error read. 
 
LED5 
ALARM display (for Axis 2) 
This LED (red) is lit when a malfunction occurs with 
the controller. 
A response is necessary after confirming the error 
details with the control software, or RS-232C 
command ID = 15 error read. 
 
LED6 
DSP2 operation (for Axis 1)
Always lights in approximately 1 sec. intervals if 
DSP2 start up correctly. 
 
LED7 
DSP2 operation (for Axis 2)
Always lights in approximately 1 sec. intervals if 
DSP2 start up correctly. 
 
 
Note: When connecting only one axis of the motor and operating the controller (GC-201), an error will 
always occur for the axis that is not connected. As a result, either LED4 or LED5 will light up, however, 
as there is no problem with the operation of the connected axis, use it as is.