Canon GM-1000 Manual Do Utilizador
![Canon](https://files.manualsbrain.com/attachments/4b6818c07b947b910f8cfb49338c2c63bdefaee1/common/fit/150/50/61ea34cb812b6780fe3b16f0b9221bd2f7635c65cee2473b66396d8b72cd/brand_logo.png)
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
Users Manual 1.20
73
A response is necessary after confirming the error
details with the control software, or RS-232C
command ID = 15 error read.
LED5
ALARM display (for Axis 2)
This LED (red) is lit when a malfunction occurs with
the controller.
A response is necessary after confirming the error
details with the control software, or RS-232C
command ID = 15 error read.
LED6
DSP2 operation (for Axis 1)
Always lights in approximately 1 sec. intervals if
DSP2 start up correctly.
LED7
DSP2 operation (for Axis 2)
Always lights in approximately 1 sec. intervals if
DSP2 start up correctly.
Note: When connecting only one axis of the motor and operating the controller (GC-201), an error will
always occur for the axis that is not connected. As a result, either LED4 or LED5 will light up, however,
as there is no problem with the operation of the connected axis, use it as is.