Canon Model 6401 B Manual Do Utilizador

Página de 47
6.  NFTU  COMMANDS
The  program  NFTU  is  a  simple  Field  Test  Unit  program  which  will  com-
municate  with  the  Model  6003  Data  Logger  and  display  (or  alter)  the  Data
Logger memory contents.
This  Software  Package  is  unsupported  by  UNIDATA.  This  means  that  the
software  is  supplied  ‘as  is’  and  UNIDATA  does  not  intend  to  correct  any
errors  or  make  further  improvements  to  the  package.
Memory  location  may  be  displayed  as  groups  of  4  single  bytes  or  as  a  32  bit
integer number.
6.1  OPERATION
1. Turn  the  FTU  on  using  the  “on/break”  key.
2. Plug  the  FTU   25  pin  D  type  connector  into  the  data  logger
computer connector.
3. The  FTU  will  display  the  value  of  the  cycle  counter  (location
4)
4. Press  a  key  L,  B,  P,  ASDF  or  a  ‘space’  and  wait  for  a  prompt.
5. When finished,  remove the FTU plug and turn the power off
using the “off key.
6.1.1  L  COMMAND
The  L  command  allows  you  to  enter  a  number  from  0  to  255  and  view  that
byte  LOCATION  in  the  current  block.  The  display  is  reset  to  ‘byte  mode’.
6.1.2  B  COMMAND
The  B  command  allows  you  to  enter  a  number  from  0  to  255   and  shift  to  that
BLOCK of memory for display or alteration. The display  is reset to ‘byte
mode’.
28 
Section  6.  NFTU  COMMANDS