Canon Model 6401 B Manual Do Utilizador

Página de 47
Field  Test  Unit  Software
7.7.2  “T”  -  TIME
This  command  enables  the  user  to  check  and/or  reset  the  logger’s  time  and
date.  The  Canon  X-07’s  date  and  time  MUST  be  set  accurately  for  this  pro-
cedure.  If  the  Canon’s  time/date  needs  to  be  changed  type  “t”  to  reset  it,  (see
below  under  X-07  Commands).
EXAMPLE:
Press “T”
FTU  display  responds:
10:58:28 
10:45:21
87/05/29 
87/05/28
logger 
canon
Press Return or Put
If the date on the logger side is as desired then press RETURN to exit. If
not the press Put  -  “P”  to  set  the  logger’s  date  to  that  of  the  Canon.
7.7.3 “d” -  DISPLAY  *
This  command  causes  the  FTU   to  display  current  information  from  the  log-
ger on:
•   Cycle time of the logger
•   Log  size  (number  of  bytes  used  per  log)
•   Log  interval  in  minutes  and  seconds
•   Time  of  the  first  log,  the  number  of  logs  made  and  the
number  of  full  days  the  logger  has  been  recording
EXAMPLE:
Press shift-D (“d”)
FTU  display  responds:
1  second  logger
1  byte  log  size
1  min  0  second
log  interval
First   log  at
12:09:00  87/05/29
3 logs  0  days
press  RETURN
3 6  
Section  7.  FTUC  COMMANDS