Hitachi kp-f500pcl/scl Manual Do Utilizador

Página de 41
14 
 
1. Send data (Setting command. Note: 1 to 7 and SUM need to be transformed into ASCII code) 
 
7
Item 
STX
STATUS ID NO.
AREA 
ADDRESS
RELATIVE
NO.
DATA 
ETX
SUM
OFF 
02
01 
FF 
01 
04 
00 
00 
00
03
28 
FIXED 
02
01 
FF 
01 
04 
01 
00 
00
03
27 
1TRIG 
02
01 
FF 
01 
04 
02 
00 
00
03
26 
MODE 
VD CONT 
02
01 
FF 
01 
04 
04 
00 
00
03
24 
POSITIVE 
02
01 
FF 
01 
0F 
00 
00 
00
03
16 
POLARITY 
NEGATIVE 
02
01 
FF 
01 
0F 
01 
00 
00
03
15 
CL-CC1 
02
01 
FF 
01 
05 
00 
00 
00
03
26 
TRIGGER 
SOURCE 
12pin 
02
01 
FF 
01 
05 
01 
00 
00
03
25 
OFF 
02
01 
FF 
01 
06 
00 
00 
00
03
26 
FLASH OUT 
02
01 
FF 
01 
06 
01 
00 
00
03
25 
OUTPUT SIGNAL 
VD 
02
01 
FF 
01 
06 
02 
00 
00
03
24 
OFF 
02
01 
FF 
01 
08 
00 
00 
00
03
24 
1/16 
02
01 
FF 
01 
08 
01 
00 
00
03
23 
1/60 
02
01 
FF 
01 
08 
02 
00 
00
03
22 
1/100 
02
01 
FF 
01 
08 
03 
00 
00
03
21 
1/250 
02
01 
FF 
01 
08 
04 
00 
00
03
20 
1/1000 
02
01 
FF 
01 
08 
05 
00 
00
03
1F 
1/2000 
02
01 
FF 
01 
08 
06 
00 
00
03
1E
1/10000 
02
01 
FF 
01 
08 
07 
00 
00
03
1D
1/50000 
02
01 
FF 
01 
08 
08 
00 
00
03
1C
PRESET 
VARIABLE (*2) 
02
01 
FF 
01 
08 
FF 
00 
00
03
F8 
MIN (1/100000(s)) 
02
01 
FF 
01 
11 
00 (*3)  00 (*3) 
00
03
2A
SHUTTER 
SPEED 
(*1) 
VARIABLE VALUE 
(2Byte) (*2) 
MAX (10(s)) 
02
01 
FF 
01 
11 
06 (*3)  00 (*3) 
00
03
1E
BASE 
02
01 
FF 
01 
12 
00 
00 
00
03
29 
CONFIGURATION 
MEDIUM 
02
01 
FF 
01 
12 
01 
00 
00
03
28 
8bit 
02
01 
FF 
01 
14 
00 
00 
00
03
27 
10bit 
02
01 
FF 
01 
14 
01 
00 
00
03
26 
DATA BIT 
12bit 
02
01 
FF 
01 
14 
02 
00 
00
03
25 
VD 
02
01 
FF 
01 
15 
00 
00 
00
03
26 
VD/FVAL 
FVAL 
02
01 
FF 
01 
15 
01 
00 
00
03
25 
HD 
02
01 
FF 
01 
16 
00 
00 
00
03
25 
LVAL 
02
01 
FF 
01 
16 
01 
00 
00
03
24 
HD/LVAL 
LVAL2 
02
01 
FF 
01 
16 
02 
00 
00
03
23 
MIN (0) 
02
01 
FF 
01 
0C 
00 (*4)  00 (*4) 
00
03
19 
GAIN (2Byte) 
MAX (503/336) (*4)  02
01 
FF 
01 
0C 
01 (*4)  F7/50(*4) 00
03
FB/13
MIN (0) 
02
01 
FF 
01 
17 
00 (*5) 
00 
00
03
24 
BLACK LEVEL 
MAX (63) 
02
01 
FF 
01 
17 
3F (*5) 
00 
00
03
0B
OFF 
02
01 
FF 
01 
13 
00 
00 
00
03
28 
VERTICAL 2 PIXEL 
ADDITION (*6)
 
ON 
02
01 
FF 
01 
13 
01 
00 
00
03
27 
OFF 
02
01 
FF 
01 
1E 
00 
00 
00
03
16 
MODE 
ON (*6) 
02
01 
FF 
01 
1E 
01 
00 
00
03
15 
MIN (1) 
02
01 
FF 
01 
1F 
00 
01 
00
03
14 
START 
(2BYTE) (*7) 
MAX (2058) 
02
01 
FF 
01 
1F 
08 (*8)  0A (*8) 
00
03
FC
MIN (1) 
02
01 
FF 
01 
20 
00 
01 
00
03
29 
PARTIAL 
SCAN 
WIDTH 
(2BYTE) (*7) 
MAX (2058) 
02
01 
FF 
01 
20 
08 (*8)  0A (*8) 
00
03
11 
 
  (*1) SHUTTER SPEED settings are effective only in the condition TRIGGER MODE is OFF or FIXED SHUTTER. 
  (*2) VARIABLE VALUE can be set only when VARIABLE is selected. 
  (*3) VARIABLE VALUE: selectable in the range from 0000 to 0600
16
 (See page 5 to 6 about setting shutter speed). 
  (*4) GAIN: selectable in the range from 0000
16
 to 01F7
16 
: KP-F500PCL/SCL. 
 
 
 
    from 0000
16
 to 0150
16 
: KP-FR500PCL/SCL. 
  (*5) BLACK LEVEL: selectable in the range from 00
16
 to 3F
16
  (*6) VERTICAL 2 PIXEL ADDITION is only for KP-F500PCL/SCL. 
  (*7) PARTIAL SCAN START/WIDTH can be set only when PARTIAL SCAN MODE is ON. 
  (*8) PARTIAL SCAN START/WIDTH: selectable in the range from 0001
16
 to 080A
16
 and the sum total of START and WIDTH is 080A
16
 or less. 
   
Command list