( 5 )   RR (Reset restart)
Input of an external reset-restart signal (CC4 of the DIGITAL terminal: External VD input) permits one screen
of information to be output at an arbitrary timing.
(5. 1) Long Term Exposure
When a sufficient sensitivity is not obtained with the normal operating conditions or capturing the trail of a
moving subject is desired, the reset-restart function allows high-sensitivity images by extending the exposure
time. To achieve this, please input from an external source a VD signal that has an expanded VD pulse and VD
pulse interval.
(5. 2) Input Timing Chart Example
1 frame
External HD IN
External VD IN
(Internal VD)
About 1H
V reset
Exposure period
External VD interval: more than 1 frame
Exposure period
Exposure period
About 1H
V reset
1 frame=  525H (Partial scanning OFF)
                262H (Partial scanning 120fps)
                175H (Partial scanning 180fps)
RGB data 
(video interval image)
FVAL
LVAL, 
DVAL
IK-TF5C(E)
05.3.14, 14:58
Page 30
Adobe PageMaker 6.5J/PPC