Hoshizaki FD-1001MLH(-C) Manual Do Utilizador

Página de 44
17
F. Installation of Remote Condenser Unit
 WARNING
1. Installation of remote condenser unit must be performed by properly trained 
and EPA-certified service personnel.
. Failure to install the equipment within these guidelines may adversely affect 
safety, performance, component life, and warranty coverage.
1. Checks Before Installation
1) Remove the shipping carton, tape, and packing material.
) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the 
fan blade moves freely.
2. Location
CAUTION
The remote condenser unit is intended for outdoor use. Normal operating 
ambient temperature should be within -0°F  to +1°F (-9°C to +50°C). 
Operation of the remote condenser unit, for extended periods, outside of this 
normal temperature range may affect icemaker performance.
The remote condenser unit must be positioned in a permanent site under the following 
guidelines:
• A firm and flat site.
• A dry and well ventilated area with 4" (61 cm) clearance in both front and rear for 
proper air circulation and ease of maintenance and/or service should they be required.
• The maximum line length for the standard refrigerant charge is 66 feet. Should an 
installation require a longer line length, line sizes must be increased and additional 
refrigerant must be added. Instead of the standard 3/8" OD discharge line and 
1/4" OD liquid line for this icemaker, increase the line sizes to 1/" OD discharge 
line and 3/8" OD liquid line for the entire run. Add 16.5 oz. of R-404A to the system 
to compensate for the larger diameter line sizes, then additional refrigerant must be 
added. Add .4 oz. of R-404A for each foot over 66 feet to a maximum of 100 feet. 
Hoshizaki Technical Support is available at 1-800-33-1940 for recommendations.
• The maximum vertical distance between the remote condenser unit and the icemaker 
is 33 feet above or 10 feet below the icemaker. These distances are measured fitting to 
fitting.
Fig. 4
Min. 4" (61 cm) Clearance
Air
Air