Avanti ER2002CSS Manual Do Proprietário

Página de 40
 
17 
Screws
Terminal Block 
Access Plate
 
 
Bracket
Power Cord
Power Wires
Neutral Wire
Cut Ground Strap
Terminal Block
 
Grounding Screw
Grounding Wire
Bracket
Power Cord
Power Wires
Neutral Wire
Terminal Block
Cut Ground Strap
 
3-Wire Power Cord Installation 
•  Remove the Terminal Block Access Plate on the back 
of range by removing the 2 fixing screws. 
•  Assemble the strain relief in the hole on bracket. 
•  Insert the power cord through the strain relief and 
tighten. 
•  Allow enough slack to easily attach the cord terminals 
to the terminal block. 
•  Remove the 3 wire terminal nuts and washers from 
the terminal block. 
•  Plug the terminal holes of power cord. The neutral or 
ground wire of the power cord must be connected to 
the neutral terminal located in the center of terminal 
block. The power leads must be connected to the 
outside terminals. 
•  Plug washers and tighten nuts securely. 
•  Assemble the Terminal Block Access Plate. 
 
 
 
 
 
 
 
4-Wire Power Cord Installation 
•  Remove the Terminal Block Access Plate on the back 
of range by removing the 2 fixing screws. 
•  Assemble the strain relief in the hole on bracket. 
•  Insert the power cord through the strain relief and 
tighten. 
•  Allow enough slack to easily attach the cord terminals 
to the terminal block. 
•  Remove the 3 wire terminal nuts and washers from 
the terminal block. 
•  Remove the ground strap from the frame of range and 
terminal by removing its screw and cutting is as 
shown. 
•  Plug the terminal holes of power cord. The neutral wire of the power cord must be connected to 
the neutral terminal located in the center of terminal block. The ground wire of the power supply 
cord must be attached to the frame of range by using the green colored grounding screw. The 
power leads must be connected to the outside terminals. 
•  Plug washers and tighten nuts securely. 
•  Assemble the Terminal Block Access Plate. 
 
 
¬ 
U
LEVELING THE RANGE 
The range must be level to obtain proper operating. The four screws 
type leveling legs located on the corners at the bottom of range should 
be adjusted by turning them clockwise to make the range higher or 
counter-clockwise to lower the range until the range is level. Use a 
level on surface units to check the leveling of the range.