Specifications
SYSTEM
Operating System
Linux
RAID Level
CompactFlash system drive, RAID 6 for storage drives
Effective Capacity
Up to 9.082 TB, expandable with DAS5200s
Drive Interface
SAS/SATA II
User Interface
Remote operation from Endura workstation or VCD5000 
Minimum Requirements
Microsoft
®
 Internet Explorer
®
 6.x or higher with Adobe
® 
Flash
®
 Player 10 or later
NETWORK
Interface
2, 1 Gbps Ethernet RJ-45 ports (1000Base-T)
Auxiliary Interfaces
USB 2.0
3 ports: 2 ports on rear panel, 1 port on front panel
FRONT PANEL INDICATORS
Power
Blue Pelco badge
Software Status
Green, Amber, Red (based on diagnostics)
Ethernet Port 1
Green, Amber, Red
Ethernet Port 2
Reserved
Hardware Status
Green, Amber, Red
Hard Drive Status
Green, Red
POWER
Power Input 
100 to 240 VAC, 50/60 Hz, autoranging
Power Supply
Internal, dual-redundant, hot-swappable
Power Consumption
Operating Average
 
262 W, 2.65 A, 895 BTU/H
 
263 W, 2.31 A, 895 BTU/H
 
254 W, 1.25 A, 868 BTU/H
Power Cord
1, USA standard (117 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or
 
1, European standard (220 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or
 
1, UK standard (250 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or 
 
2, Australian (250 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or
 
2, Argentinian (250 VAC, 3 prongs, molded connector, 8 ft or 2.4 m)
NOTE:  Units shipped to China do not include power cords.
ENVIRONMENTAL
Operating Temperature
50° to 95°F (10° to 35°C) at unit air intake
Storage Temperature
-40° to 149°F (-40° to 65°C)
Operating Humidity
20% to 80%, noncondensing
Maximum Humidity Gradient
10% per hour 
Operating Altitude
-50 to 10,000 ft (-16 to 3,048 m)
Operating Vibration
0.25 G at 3 Hz to 200 Hz at a sweep rate of 0.5 octave/minute
NOTE:  The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configuration, 
floor layout, air conditioning strategy, and other issues. To prevent performance failure and unit damage, make sure the temperature at the unit is 
continuously within the operating temperature range.