Festool PI571810 Manual Do Utilizador

Página de 40
6
Extension cord 
If an extension cord is required, it must 
have suffi cient cross-section to prevent an 
excessive drop in voltage or overheating. 
An excessive drop in voltage reduces the 
output and can lead to failure of the motor. 
The table below shows you the correct cord 
diameter as a function of the cord length for 
the RO 150 FEQ.
Use only U.L. and CSA listed extension cords. 
Never use two extension cords together. In-
stead, use one long one.
Note: The lower the AWG number, the stron-
ger the cord.
Electronic control 
ELECTRONIC
  The tool has full-wave electronics with 
the following features:
Smooth start-up 
The smooth start-up ensures jolt-free start-
up.
Speed adjustment 
You can regulate the speed steplessly between 
3300 and 6800 rpm using the adjusting wheel 
(3.1). This lets you optimize the sanding 
speed to suit the material.
Constant speed 
The pre-selected speed remains constant 
whether the tool is in operation or in neutral 
position.
Temperature control 
To prevent overheating, the safety electronics 
switch the tool off when it reaches a critical 
motor temperature. Let the tool cool down 
for approx. 3-5 minutes before using it again. 
The tool requires less time to cool down if it 
is running, i.e. in neutral position.
Total Extension Cord 
Lenght (feed)
25
50
100 150
Cord size (AWG)
18
16
16
14
3.1