Powermatic 1791228K Manual Do Utilizador

Página de 36
230 Volt Conversion 
 
If 230V single phase operation is desired, follow 
these instructions: 
1.  Disconnect tablesaw from power source. 
2.  Open the motor junction box, and consult 
the diagrams affixed to the inside of the 
junction box cover. These diagrams are also 
shown in Figures 2 and 3. This saw is 
supplied with four motor leads that are 
connected for 115V operation (Figure 2). 
Reconnect these four motor leads for 230V 
operation (Figure 3). 
3.  The 115V attachment plug, supplied with 
the saw, must be replaced with a UL/CSA 
listed plug suitable for 230V operation. 
Consult an electrician for proper procedures 
to install the plug. The saw must comply 
with all local and national codes after the 
230V plug is installed. 
In all cases (115V or 230V) make certain the 
receptacle in question is properly grounded. 
If you are not sure, have a registered 
electrician check the receptacle. 
 
 
 
 
 
 
 
 
 
 
 
Extension Cords 
If an extension cord is necessary, make sure the 
cord rating is suitable for the amperage listed on 
the machine’s motor plate. An undersize cord 
will cause a drop in line voltage resulting in loss 
of power and overheating. 
Use the chart in Figure 4 as a general guide in 
choosing the correct size cord. If in doubt, use 
the next heavier gauge. The smaller the gauge 
number, the heavier the cord. 
 
 
Figure 2 
 
Figure 3 
 
Recommended Gauges (AWG) of Extension Cords 
Extension Cord Length *  
Amps 
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
5  16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 to 20 
10 
10 
10 
NR 
NR 
NR 
21 
to 
30  10  NR NR NR NR NR 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended. 
Figure 4