Standard Control Panel 
Revision – 1.00 
 
 
Intel order number D31980-004 
59
 
6.2.1 
Power / Sleep LED 
Table 44. SSI Power LED Operation 
State 
Power Mode 
LED 
Description 
Power Off 
Non-ACPI 
Off 
System power is off, and the BIOS has not initialized the chipset. 
Power On 
Non-ACPI 
On 
System power is on, but the BIOS has not yet initialized the chipset. 
S5 
ACPI 
Off 
Mechanical is off, and the operating system has not saved any context 
to the hard disk. 
S4 
ACPI 
Off 
Mechanical is off. The operating system has saved context to the hard 
disk. 
S3-S1 
ACPI 
Slow blink 1 
DC power is still on. The operating system has saved context and 
gone into a level of low-power state. 
S0 
ACPI 
Steady on 
System and the operating system are up and running. 
Notes: 
1.  Blink rate is ~ 1Hz with at 50% duty cycle.  
 
6.2.2 
System Status LED 
Table 45. Control Panel LED Operation 
Color 
State 
Criticality 
Description 
Off 
N/A 
Not ready 
AC power off 
Green/
Amber 
Alternating 
Blink 
Not ready 
Pre DC Power On – 15-20 second BMC Initialization when 
AC is applied to the server. Control Panel buttons are 
disabled until BMC initialization is complete. 
Green 
Solid on 
Ok 
System booted and ready 
Green 
Blink  
Degraded 
System degraded 
  Unable to use all of the installed memory (more than one 
DIMM installed). 
  Correctable errors over a threshold of 10 and migrating to 
a spare DIMM (memory sparing). This indicates that the user 
no longer has spared DIMMs indicating a redundancy lost 
condition. Corresponding DIMM LED should light up. 
  In mirrored configuration, when memory mirroring takes 
place and system loses memory redundancy. This is not 
covered by (2). 
  Redundancy loss such as power-supply or fan. This does 
not apply to non-redundant sub-systems. 
  PCIe* link errors 
  CPU failure / disabled – if there are two processors and 
one of them fails 
  Fan alarm – Fan failure. Number of operational fans 
should be more than minimum number needed to cool the 
system 
  Non-critical threshold crossed – Temperature and voltage 
Amber Blink 
Non-critical 
Non-fatal 
alarm – system is likely to fail 
  Critical voltage threshold crossed 
  VRD hot asserted 
  Minimum number of fans to cool the system not present 
or failed 
  In non-sparing and non-mirroring mode if the threshold of 
ten correctable errors is crossed within the window