Grounding
3A0156A
7
Grounding
The sprayer must be grounded. Grounding reduces the 
risk of static and electric shock by providing an escape 
wire for the electrical current due to static build up or in 
the event of a short circuit.
The sprayer cord includes a grounding wire with an 
appropriate grounding contact.
The plug must be plugged into an outlet that is properly 
installed and grounded in accordance with all local 
codes and ordinances.
Do not modify plug! Tampering with the plug will result in 
a voided warranty. If plug will not fit in outlet, have 
grounded outlet installed by a qualified electrician. Do 
not use an adapter.
Power Requirements
100-120V units require 100-120 VAC, 50/60 Hz, 
15A, 1 phase.
230V units require 230 VAC, 50/60 HZ, 
10A, 1 phase.
Extension Cord
Use an extension cord with an undamaged ground con-
tact. If an extension cord is necessary, use a 3-wire, 12 
AWG (2.5 mm
2
) minimum.
Pails
Solvent and oil/based fluids: follow local code. Use 
only conductive metal pails, placed on a grounded sur-
face such as concrete. 
Do not place pail on a nonconductive surface such as 
paper or cardboard which interrupts grounding continu-
ity.
Grounding a metal pail: connect a ground wire to the 
pail by clamping one end to pail and other end to a true 
earth ground.
To maintain grounding continuity when flushing or 
relieving pressure:
 hold metal part of spray gun firmly 
to side of a grounded metal pail. Then trigger gun.
ti4297a
ti2810a
Ground
120 volt plug
 
ti5850a
ti14840a
ti13243a