Setup 
4
312388K
Setup
Connecting Air Line
1. Install an air pressure regulator on gun air 
supply line to control air pressure.
2. Install a shutoff valve downstream of the air 
regulator to shut off gun air.
3. Connect a clean, dry, filtered air supply to 
air inlet fitting (13). Connect other end to 
shutoff valve.
Connecting Fluid Supply
Pressure feed guns:
1. To control fluid 
pressure to the gun, 
install a fluid regulator 
on the fluid line.
2. Connect the fluid hose 
to the gun fluid inlet, 
3/8-18 npsm (R3/8-19) 
(21).
3. Connect other end to a 
regulated fluid supply line.
Gravity feed guns:
1. Install fluid filter 
(24) into fluid 
inlet (A).
2. Screw on gravity 
cup.
3. Remove gravity 
cup cover and fill 
cup with solvent 
to flush if this is 
first time using 
equipment. (See 
Flushing, page 
6.)
4. After flushing, fill 
cup with fluid and 
attach cover.
Reference numbers and letters in paren-
theses in the text refer to numbers and 
letters in the illustrations.