Graco Inc. ti12872a Manual Do Utilizador

Página de 8
Technical Data 
6
313317C
Technical Data
No or slow fluid flow, intermit-
tent spray, or fluttering spray
Wrong size fluid set being used
Select proper fluid set for fluid being sprayed, 
page 4
Gun fluid nozzle blocked by dried 
paint or damaged
Clean or replace fluid nozzle
Cup or pressure pot cover not tight 
enough or gasket damaged
Tighten cover or replace gasket
Cup or pressure pot fluid tubes 
blocked by dried paint or damaged
Clean or replace fluid tubes
Air flow to cup blocked
To check, remove cup (leave cover connected). 
Trigger gun and check air flow out of check 
valve. If air is not flowing freely, clean or replace 
check valve.
Needle packings not properly 
adjusted. 
Note: Fluid loss through packings 
affects fluid pressure and causes a 
fluid leak from gun body.
Clean gun body with solvent and brush pro-
vided. Adjust needle packings.
Plugged inlet strainer
Replace strainer if plugged or remove strainer if 
material is high viscous.
Fluid leaks at fluid nozzle 
after trigger is released
Needle not seating in fluid nozzle
Check for a loose fluid nozzle or a bent nozzle 
or needle; tighten nozzle or replace parts as 
needed.
Poor spray pattern
Air cap horn hole and/or fluid nozzle 
plugged
Soak air cap and/or fluid nozzle in solvent. 
Clean air cap horn holes with non-metallic item 
to avoid permanently damaging them.
Problem
Cause
Solution
Maximum inlet fluid pressure
50 psi (0.35 MPa, 3.5 bar)
Maximum inlet air pressure
10 psi (0.07 MPa, 0.7 bar)
Air inlet
Quick-disconnect
Fluid inlet
3/8 nps
Sound levels per ISO 3744
Sound power level
less than 65.0 dB(A)
Sound pressure level
less than 65.0 dB(A)
Wetted parts
Bare spray gun
stainless steel, aluminum
Spray gun cups
aluminum, polyethylene
1-quart optional remote cup
aluminum, polyethylene