Graco Inc. ti3810a Manual Do Utilizador

Página de 16
Service 
10
309739
Reassembly
Clean all parts thoroughly before reassembling. Check 
them carefully for damage or wear, replacing parts as 
needed. For best results replace the original parts with 
new parts in repair kits.
Prior to assembly, lubricate all seals and o-rings with 
PARKER-O-LUBE or an equivalent lubricant. 
1.
Connect needle (8) and stop nut (2) to yoke (1).
2.
Secure yoke (1) in soft jawed vise. Lock stop nut (2) 
against yoke.
3.
Insert needle (8) into packing nut (5). 
4.
Push three seal needles (6) in packing nut (5) using 
soft rod or dowel. Orient as shown below
5.
Install o-ring (4) on groove of packing nut (5).
6.
Install guide (22) on needle (8).
7.
Rewind spiral o-ring backup (21) on guide (22).
8.
Install two o-rings (23) on guide (22).
9.
Insert cartridge assembly in gun body (17) from rear 
of gun.
10. Screw packing nut (5) into gun body (17).
11. Insert valve (20) through front of gun on needle (8).
12. Tighten nut (19) on needle (8).
13. Adjust screw (3) to tighten packings.
14. Install trigger (18). Align yoke (1) in gun body (17). 
15. Press trigger pin (12) into gun body.
16. Secure trigger pins (12) using screws (11) and lock 
washers (28).
17. Install spring (13) and spring retainer (15) into gun 
body (17).
18. Adjust spring retainer to allow approximately 1/32 in. 
of free play on trigger.
19. Tighten stop nut (14).
20. Install o-ring (10) on adapter (9).
21. With trigger retracted screw adapter (9) on gun body 
(17).
22. While holding adapter (9) stationary, screw collar 
(16) and nozzle into adapter. Do not over tighten 
collar.
23. Reconnect flow gun to material supply line.
24. Turn on material supply line to gun.
25. Return flow gun to normal operating condition.
ti4043a
ti4045a
ti4050a
ti4051a