Troubleshooting
309293K
35
Visual Check
First, check the system for any visible faults or errors to 
help isolate whether the spray gun, fluid hose or voltage 
isolation system has failed. A voltage probe and meter, 
part no. 236003, is helpful for diagnosing voltage prob-
lems and is required for some of the troubleshooting 
tests that follow.
1.
Check that all of the air and fluid tubes and hoses 
are properly connected. 
2.
Check that the voltage isolation system valves and 
controls are properly set for operation. 
3.
Check that the interior of the isolated enclosure is 
clean.
4.
Check that the spray gun and voltage isolation sys-
tem have sufficient air pressure.
5.
Check that the gun ES ON/OFF valve is in the ON 
position and that the gun ES indicator light is on. If 
the ES indicator light is not on, remove the spray 
gun for service and complete the electrical tests on 
pages 30- 32.
6.
Check that the voltage isolation system's enclosure 
door is closed and that any safety interlocks are 
engaged and working properly.
7.
Make sure the voltage isolation system is in the “iso-
late” mode, where it is isolating the fluid voltage 
from ground.
8.
To eliminate air gaps in the fluid column, spray 
enough fluid to purge the air out between the volt-
age isolation system and the spray gun. An air gap 
in the fluid hose can break the electrical continuity 
between the spray gun and the isolated fluid supply 
and cause a low voltage reading on a voltage meter 
connected to the isolated fluid supply.
9.
Check the spray gun cover and barrel for accumu-
lated overspray. Excessive overspray can create a 
conductive path back to the grounded gun handle. 
Install a new gun cover and clean the exterior of the 
gun.
10. Inspect the entire system for any visible fluid leak-
age and repair any fluid leaks that are found. Pay 
special attention to the following areas: 
Packing area of the spray gun
Fluid hose: check for leakage or any bulges in the 
outer cover, which may indicate an internal leak
Internal voltage isolation system components
Tests
If you still have no voltage, separate the spray gun and 
hose from the voltage isolation system and check 
whether the gun and hose alone will hold voltage with 
the following test.
1.
Flush the system with water and leave the lines 
filled with water.
2.
Discharge the system voltage (page 20).
3.
Relieve the pressure (page 20).
4.
Disconnect the fluid hose from the voltage isolation 
system.
Avoid allowing any water to leak out of the fluid hose as 
that could cause a significant air gap in the fluid column 
up to the gun electrode, which can break the conductiv-
ity path and conceal a potential failure area.
5.
Position the end of the hose as far as possible away 
from any grounded surface. The end of the hose 
must be at least 1 ft. (0.3 m) from any ground. Make 
sure that no one is within 3 ft. (0.9 m) of the end of 
the hose.
6.
Turn the ES ON/OFF valve to ON and trigger the 
gun just enough to turn on the air to the gun but not 
the fluid. Measure the voltage at the gun electrode 
with a voltage probe and meter.
7.
Discharge the system voltage by waiting 30 sec-
onds and then touching the gun electrode with a 
grounded rod.
8.
If the meter reading is 45 to 55 kV, the gun and fluid 
hose are okay, and the problem is in the voltage iso-
lation system. 
If the reading is below 45 kV, the problem is in the 
gun or fluid hose.