Graco Inc. 7900HD Manual Do Utilizador

Página de 16
Startup 
8
3A0242A
8.
Hold gun against grounded metal flushing pail. Trig-
ger gun and increase fluid pressure slowly until 
pump runs smoothly.
Inspect fittings for leaks. Do not stop leaks with your 
hand or a rag! If leaks occur, turn sprayer OFF 
immediately. Perform Pressure Relief Procedure 
steps 1-3, page 5. Tighten leaky fittings. Repeat 
Startup procedure steps 1 - 5. If no leaks, continue 
to trigger gun until system is thoroughly flushed. 
Proceed to step 6.
9.
Place siphon tube in material pail. 
10. Trigger gun again into flushing fluid pail until mate-
rial appears.
Switch Guard Assembly
1.
Put trigger safety ON. Insert SwitchTip. Insert seat 
and OneSeal
.
2.
Insert SwitchTip.
3.
Screw assembly onto gun. Tighten.
Spray
1.
Spray test pattern. Increase pressure to eliminate 
heavy edges. Use smaller tip size if pressure adjust-
ment can not eliminate heavy edges.
2.
Hold gun perpendicular, 10-12 in. (25-30 cm) from 
surface. Spray back and forth. Overlap by 50%. Trig-
ger gun after moving and release before stopping.
ti13243a
ti5796a
ti5797a
ti13243a
C
A
B
ti13024a
ti2710a
ti13030a
ti13025a