Graco ProX7 & ProX9 Manual Do Utilizador

Página de 52
Basic Troubleshooting
312667K
13
Basic Troubleshooting
Check everything in this Basic Troubleshooting table before you bring the sprayer to a Graco/M
AGNUM
 authorized 
service center. 
Problem
Cause
Solution
Power switch is on and sprayer is 
plugged in, but motor does not run, 
and pump does not cycle.
Pressure is set at zero pressure.
Turn pressure control knob clockwise 
to increase pressure setting.
Electric outlet is not providing power. •
Check that lighted plug on 
sprayer is lit (this indicates 
electric power at outlet).
Reset building circuit breaker or 
replace fuse.
Extension cord is damaged.
Replace extension cord. Read 
Grounding and Electric Require-
ments
, page 10.
Sprayer electric cord is damaged.
Check for broken insulation or wires. 
Replace electric cord if damaged.
Motor or control is damaged.
Take sprayer to Graco/M
AGNUM
 
authorized service center.