Graco 16H245 Manual Do Utilizador

Página de 32
Storage 
18
3A1698F
Cleaning Sprayer Exterior
Wipe paint off outside of sprayer using a soft cloth 
moistened with water or flushing fluid. 
Do NOT submerge the sprayer.
Fine Finish Tip Wear
Fine Finish Tip/Guard assembly may require 
replacement depending on abrasiveness of paint.
Do not spray with worn tip. See Troubleshooting
page 26.
Storage
1.
Dilute 4 oz. bottle of Pump Armor Concentrate with 
an additional 4 oz. of water in material cup.
2.
Thread cup into sprayer, put prime/pressure relief 
valve to UP position and squeeze sprayer trigger for 
approximately 10 seconds.
3.
Reverse spray tip to UNCLOG position, put 
prime/pressure relief valve DOWN to spray position, 
and aim sprayer into waste area. Pull trigger for 1-2 
seconds.
4.
Properly dispose of used Pump Armor mixture from 
material cup and rinse cup with water.
5.
Recharge battery to full charge before storage. See 
Charging the Battery, page 8.
6.
Store sprayer indoors in a cool, dry place. Store in 
an upright position only. Never store sprayer with 
material in the cup.
This sprayer is 
equipped with a static 
wick that reduces the 
build-up of static charge 
to reduce the risk of fire 
and explosion. KEEP 
THIS SURFACE 
CLEAN OF OVER-
SPRAY.
NOTICE
Failure to store sprayer with Pump Armor will result in 
operational problems the next time you spray. Always 
circulate Pump Armor through the sprayer after clean-
ing. Water or solvents other than mineral spirits 
left in the sprayer will corrode and damage the 
pump.
ti16728a
ti16951a
4 oz
ti16729a
ti16700a
ti16716a
ti15425a
ti15418a
ti14991a
ti16701a
ti14991a
ti16716a
ti16726a
ti16730a