Alternate Priming Method
3A1698F
23
Alternate Priming Method
If sprayer fails to prime, the inlet valve may be stuck due 
to paint residue. Perform the steps below.
1.
Engage trigger lock and pull prime/pressure relief 
valve UP to release pressure.
2.
Remove material cup and suction tube.
3.
Use a pencil or thin rod to lightly push on inlet valve 
to make sure it moves up and down freely.
4.
If inlet valve does not move freely, perform Inlet 
Valve Removal
, page 24. If inlet valve moves 
freely, install suction tube without strainer, turn 
sprayer upside-down, and slowly pour flushing 
material into suction tube until full.
5.
Leaving the sprayer upside-down, disengage trigger 
lock and quickly trigger sprayer until material comes 
out of drain port.
6.
Install strainer on suction tube and thread material 
cup back onto sprayer.
7.
Trigger gun for 10 seconds then release trigger and 
put prime/pressure relief valve DOWN to spray posi-
tion.
8.
Reverse spray tip to UNCLOG position and spray 
into waste area for five seconds to ensure sprayer 
has primed.
9.
Pull prime/pressure relief valve up to release pres-
sure, reverse spray tip to SPRAY position and put 
prime/pressure relief valve DOWN to spray position. 
Sprayer is now ready to spray. Perform Starting 
New Job
 procedure, page 13.
Move sprayer to a non-hazardous area before servicing.
ti14994a