Digital Display Messages
332919C
31
Digital Display Messages
Digital messages are not available on all sprayers
Blinking LED total count equals digital error code 
i.e., two blinks is the same as E=02
* Error codes also appear on control board as a blinking red 
LED. LED is an alternate to digital messages.
1.
Remove two screws (71) and swing down cover (130).
2.
Start engine. Blink count is the same as error code(E=0X).
After a fault, follow these steps to restart sprayer:
1.
Correct fault condition
2.
Turn sprayer OFF
3.
Turn sprayer ON
DISPLAY*
SPRAYER OPERA-
TION
INDICATION
ACTION
No Display
Sprayer may be 
pressurized.
Loss of power or display 
not connected.
Check power source. Relieve pressure before repair 
or disassembly. Verify display is connected.
Sprayer may be 
pressurized.
Pressure less than 
200 psi (14 bar, 1.4 MPa).
Increase pressure as needed.
Sprayer is pressurized. 
Power is applied. 
(Pressure varies with 
tip size and pressure 
control setting).
Normal operation.
Spray
Sprayer stops. Engine 
is running.
Exceeded pressure limit.
1.
Check fluid path for clogs, such as clogged filter.
2.
Open prime valve and gun if running AutoClean.
3.
Use Graco paint hose, 1/4 in. x 50 ft minimum. 
Smaller hose or metal braid hose may result in 
pressure spikes.
4.
Replace transducer if fluid path is not clogged 
and proper hose is used.
Sprayer stops. Engine 
is running.
Pressure transducer faulty, 
bad connection or broken 
wire.
1.
Check transducer connection.
2.
Disconnect and reconnect transducer plug to 
ensure good connection with control board 
socket.
3.
Open prime valve. Replace sprayer transducer 
with known good transducer and run sprayer. 
Replace transducer if sprayer runs or control 
board if sprayer does not run.
Sprayer stops. Engine 
is running.
High clutch current.
1.
Check wiring connections.
2.
Measure: 1.2 + 0.2 
Ω (GMAX II 3900); 
1.7 + 0.2
 Ω (GMAX II 5900/ 7900 & TexSpray 
7900HD) across clutch field at 70°F.
3.
Replace clutch field assembly.
(with constant 
green LED)
Sprayer stops. Engine 
is running.
Loss of paint to pump or 
severe pressure loss.
1.
Check for empty paint condition, clogged inlet 
strainer, failed pump or severe leak.
2.
Reduce pressure and turn pump switch OFF 
and ON to restart pump.
3.
WatchDog function can be deactivated by 
turning WatchDog switch OFF.
Sprayer stops. Engine 
is running.
Pressure greater than 
2000 psi (138 bar, 14 MPa) 
while in Flush Timer Mode.
1.
Open prime valve and gun.
2.
Verify no flow obstructions or clogged filter.