Cisco Systems RPS 675 Manual Do Utilizador

Página de 104
 
1-3
Cisco RPS 675 Redundant Power System Hardware Installation Guide
78-15201-04
Chapter 1      Product Overview
Front-Panel Description
  •
Front-panel LEDs to show status for each output channel, internal power 
supplies, fans, and temperature
  •
Quick switchover capability to ensure that the switch does not reboot if the 
internal switch power supply should fail
  •
Support for telephone-enabled 24-port devices
  •
Small form-factor suitable for rack-mounting to provide maximum wiring 
closet port density
  •
Two output levels:
  –
–48 VDC with a maximum output of 375 W 
  –
12 VDC with a maximum output of 300 W
The two output levels provide a maximum total output power of 675 W. 
The –48 VDC mode powers telephone systems in Power over Ethernet (PoE) 
switches.
  •
A single 48-inch (1.2-meter) 16-pin-to-14-pin connector cable 
(CAB-RPS-1614=) to allow connection to an external device. Additional 
cables can be ordered separately.
Front-Panel Description
The RPS 675 front panel includes the status LEDs for the RPS and a 
Standby/Active button.
LEDs
 shows the Cisco RPS 675 LEDs. The LEDs display the status of the 
RPS and show whether the RPS is powering a connected device. LEDs can be off, 
green, or amber. 
 lists the status LEDs and the meanings of the colors.