Requirements
•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be
wired through a switch.
Some  codes  require  installation  by  a  
qualified electrician.
•  This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Light Control
Sensor
Cover 
Plate
Lamp Holders
Features
•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  Bulb Saver™ - Extends bulb life by up to 4x standard
bulbs. Lights bulb to full bright in under 2 seconds.
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).
Plastic Hanger
Rubber Plug
Gasket
Mounting Strap
Mounting Bolt
2 Wire
Connectors
This package includes:
6 Screws
(3 sizes included)
OPERATION
* resets to Auto Mode at dawn.
TEST
10 5 1 
TEST
ON-TIME
Put  the  ON-TIME  switch  on  the
bottom of the sensor in the TEST
position.
MANUAL MODE
ON-TIME
10 5 1 TEST
... back on.
AUTO
1 Second OFF
then...
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Manual  mode  only  works  at  night
because  daylight  returns  the  sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual  mode  works  only  with  the
ON-TIME  switch  in  the  1,  5,  or  10
position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Normal
1, 5, 10 min.
x
Manual
Until Dawn*
x
Model SH-5412
Motion Sensor
Light Control
Meets the ENERGY STAR
®
guidelines
when used with 120 W Max bulbs.