Heath Zenith SL-5503 Manual Do Utilizador

Página de 4
598-1138-02
❒ Attach the cover plate to the junction box (Apply silicon 
caulk between cover plate and junction box for a raintight 
seal). Keep the fi xture horizontal (within +/- 4°) so the bulb 
inside is horizontal. If the bulb is not horizontal, the bulb 
may darken or shatter and fail prematurely.
❒  Loosen the side bolt connected to the arm to aim the fi xture 
up and down.
Bulb Installation and Relamping
Important: Use a clean glove or cloth when handling the 
new bulb. Oil from your hand may cause the bulb to crack 
when the fi xture heats up and result in premature failure. 
Use isopropyl (rubbing) alcohol to clean the bulb if it is 
touched with your bare hands.
❒ When relamping, turn power off and let the fi xture cool.
❒ Remove glass cover and remove the old bulb by pushing 
the bulb towards the right until the left side of the bulb is 
clear of the left socket.
❒ To insert the new bulb push the bulb into the right socket 
so the bulb is properly seated in the sockets.
❒ Re-install the glass cover.
❒ Reconnect the power.
Quartz Halogen Floodlight
Model SL-5503 - 300 Watts
Model SL-5505 - 500 Watts
Fixture Installation Instructions
To avoid Electrical Shock:
The Heath
®
/Zenith Quart Halogen Floodlight disperses light over a wide area. It includes a halogen lamp, attaches to a 
standard threaded junction box cover plate and is for use with 120 VAC.
FOR PROPER INSTALLATION AND OPERATION, PLEASE READ THESE INSTRUCTIONS CAREFULLY.
To Avoid Fire Or Burn Hazards:
•  Allow fi xture to cool before touching. The bulb and the fi xture operate at high temperatures.
•  Keep fi xture at least 2” from combustible materials. Do not aim at objects closer than 3 feet.
•  Use a lamp that does not exceed the maximum ratings for your model.
  Maximum ratings are: SL-5503 - 300 Watts; SL-5505 - 500 Watts.
WIRING FIXTURE
(Product May Vary from Illustration)
White to White
Black to Black
Fixture ground to 
junction box ground.
Cover Plate
No Service Parts Available for this Product
© 2007 HeathCo LLC 
598-1138-02
 WARNING: Turn power off at the circuit breaker or 
fuse.
•  Follow all warnings listed on fi xture.
•  Grounding and installations must comply with local codes 
and the National Electric Code.
•  This product should be mounted on a grounded junction 
box and must be used with a threaded cover plate.
•  Permanently mount the fi xture to a building or pole.
  Fixture is designed for WALL MOUNT ONLY (see illus-
tration below).
❒  Thread aiming arm through the cover plate (not included) and 
tighten the locknut. Apply silicon caulk for a raintight seal.
❒  Connect the lamp wires to the power source wiring. Secure 
with wire connectors.