Lightolier FH4 Folheto

Página de 2
0.0
45.0
90.0
FLUX
0
8537
8537
8537
5
8532
8393
8265
799
10
8424
7992
7495
15
8225
7324
6543
2058
20
7938
6549
5635
25
7602
5743
4703
2720
30
7179
4938
3863
35
6679
4141
3190
2797
40
6124
3358
2794
45
5510
2724
2509
2554
50
4842
2270
2174
55
4153
1959
1956
2096
60
3424
1625
1630
65
2666
1355
1138
1432
70
1943
979
750
75
1218
542
391
649
80
539
220
70
85
53
0
0
62
90
0
0
0
Surface/Pendant Mounted Fluorescent
TriLyte FH4
Page 2 of 2
17" Narrow Body, 48 or 96" Length
2, 3 or 4 Lamp T5 and T8
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: FH4C4DXX454120PV
Options/Accessories
Emergency Power Pack: Factory installed emergency power pack includes charger
and inverter concealed in fixture channel. Upon lost of AC power, operates one lamp
at high lumen output for a period of 90 minutes. Catalog Number: LP600
(std. Bodine LP600).
Electrical Wiring Options: Consult factory.
Stem and Canopy Kits: Suspend luminaire 12", 18", 24", 36" and 48" from surface.
(Four per luminaire is recommended. Catalog Number: ASC6 CSP (6"),
ASC12 CSP )12"), ASC18 CSP (18"), ASC24 CSP (24").
Chain Suspension Option: 24" Chain Suspension Kit (Two per fixture is required).
Catalog Number: EE9HC.
Sensors: Order Catalog Number: FH360 for Line Voltage Sensor. (Sold separately /
Field installed).
Specifications
Materials: Chassis parts are die-formed code 20 gauge cold rolled steel.
Finish: Chassis exterior – post painted in a baked polyester powdercoat
finish. Cavity – white baked polyester powdercoat, minimum reflectance 86%.
Specifications (continued)
Reflector – contoured or flat design specular reflector. 95% reflectivity.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
FH
TriLyte
FH4:
Heavy Duty
Surface
Luminaire
Fixture
Width
4=48"
8=96"
Reflector*:
= Contoured
Specular
= Flat Specular
= Flat White
*Not available
in 2 lamp option
with contoured
specular reflector
D
Light
Direction:
D=Direct
4
Fixture
Width:
4=17"
Model No. FH4C4DXX454120PV
LER = FP - 67.1
IW -23.6
BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.57
Report Number: LSCA590
Catalog Number: FH4C4DXX454120PV
Lamps: 54W T5HO
Luminaire: Surface/pendant, slim profile
with contoured specular reflector
Ballast: ICN-4554-90C-2LS
Report is based on 4400 Lumens per lamp.
Efficiency: 86.2%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
0.8
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
18682.
9269.
8539.
55
17358.
8220.
8205.
65
15121.
7712.
6479.
75
11286.
5023.
3636.
85
1467.
0.
0.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 96 92 89 87 85 83 84 82 80
0
2 88 83 78 78 74 71 76 72 70
0
3 82 74 68 71 66 62 68 64 61
0
4 76 67 60 64 59 54 62 57 54
0
5 70 60 53 57 52 47 56 51 47
0
6 65 55 48 52 46 42 51 46 42
0
7 60 50 43 48 42 37 46 41 37
0
8 56 45 38 43 37 33 42 37 33
0
9 52 41 34 39 33 29 38 33 29
10 48 37 31 36 30 26 35 30 26
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
5576
31.69
36.77
0
0-
0
40
8373
47.58
55.21
0
0-
0
60
13023
74.00
85.87
0
0-
0
90
15166
86.17
100.00
40-
0
90
6792
38.58
44.79
60-
0
90
2142
12.17
14.13
90-180
000
0
.00
00
.00
0
0-180
151.66
86.17
100.00
ZONAL LUMEN SUMMARY
Lightolier 
a Genlyte company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 a Genlyte company
Section 7/Folio Q40-10
Voltage:
120, 277 or UNV
UNV=120-277
Lens Shielding:
WW= White Wire-
guard/No Lens
VA = White  Wire-
guard/Pattern 
12 .095"
V
I
= White Wire-
guard/Pattern 
12 .125"
nominal lens
XX = No Shielding
Lamp
Quantity:
2=2 Lamp
3=3 Lamp
4=4 Lamp
Lamp:
32=32 Watt T8 
28=28 Watt T5
54=54 Watt T5HO
(Nominal 48") 
Ballast Type:
<
20THD
<
10THD
1-2 Lamp Elec. T8
SO *
H
I
*
*
1-3 Lamp Elec. T8
O3 *
H3 *
*
1-4 Lamp Elec. T8
O4 *
H4 *
*
1-2 Lamp & 1-4 Lamp Elec. T8
O5 *
H5 *
*
2-3 Lamp  Elec. T8
O6 *
H6 *
*
1-4 Lamp Outside, 1-4 Lamp
Inside Elec. T8
O7 *
H7 *
*
1-2 Lamp Elec. T5
P
I
1-2 Lamp Elec. T5, 28W or 54W
PG ††
1-3 Lamp Elec. T5, 54W
PU ††
1-4 Lamp Elec. T5, 54W
PV ††
1-2 Lamp & 1-4 LampElec. T5, 54W
P6 ††
1-3 Lamp (for Lamps 1, 3, 5) &
1-3 Lamp (for 2, 4, 6) Elec. T5, 54W
P7 ††
1-4 Lamp Outside Lamps & 1-4
Lamp Inside Lamps  T5, 54W
P8 ††
*Instant Start Standard (120, 277 or UNV)
†Instant Start Standard (120, 277)
††Program Start Rapid Start (UNV only)
Ballast Type:
NOTE:
See Above