Campbell Hausfeld WS4469 Manual Do Utilizador

Página de 48
2
www.chpower.com
Operating Instructions and Parts Manual
WS4369 and WS4469
Circuit Requirements
 
This equipment   
  requires a 
dedicated 230 volt circuit. Refer to the 
Specifications section for the correct 
circuit breaker or fuse rating. Do not 
run other appliances, lights, or tools 
on this circuit while operating this 
equipment. Extension cords are not 
recommended. Blown fuses and tripped 
circuit breakers can result from failure 
to comply with this recommendation.
 
The electrode holder  
  is "live" (has current 
potential) when machine is turned on.
Safety Guidelines
This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.
 
Danger indicates  
  an imminently 
hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.
 
Warning indicates  
  a potentially 
hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 
Caution indicates  
  a potentially 
hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 
Notice indicates  
  important 
information, that if not followed, may 
cause damage to equipment.
General Safety Information
CAlIfORnIA PROPOSITIOn 65
 
The cables on this
  product may contain 
chemicals, including lead, known to 
the State of California to cause cancer 
and birth defects or other reproductive 
harm. Wash hands after handling.
To request Material Safety Data Sheet 
(MSDS), visit the Internet at www.
chpower.com or call 1-800-746-5641.
 
This product, when 
  used for welding, 
produces fumes or gases which contain 
chemicals known to the State of 
California to cause birth defects (or 
other reproductive harm) and, in some 
cases, cancer (California Health & Safety 
Code Section 25249.5 et seq.)
GeneRAl
 •  Before starting or 
servicing any electric 
arc welder, read and 
understand all instructions. Failure 
to follow safety precautions or 
instructions can cause equipment 
damage and or serious personal 
injury or death. For additional 
safety information, obtain a copy 
of ANSI Standard Z49.1 - Safety 
in Welding and Cutting. This 
publication may be ordered from 
the American Welding Society, 550 
NW LeJeune Road, Miami, FL 33126
MANUAL
Components and Controls
1.  Work Clamp – connect to work 
piece
2.  Electrode Holder – holds welding 
electrode.
3.  Power Cord – plug into 230 volt 
outlet.
4.  ON / OFF Switch
5.  Infinite Amperage Control Knob – 
turns clockwise to increase 
amperage and counterclockwise to 
decrease amperage.
6.  Welding Amp Indicator – as the 
amperage control knob (5) is 
rotated, the amperage indicator 
moves, displaying approximate 
weld amps.
7.  Overload Indicator Light – lights 
when duty cycle exceeded.
1
2
3
4
5
6
7
figure 1