General Troubleshooting  
 
S
YMPTOM
 
P
OSSIBLE 
C
AUSE
(
S
P
OSSIBLE 
A
CTION
(
S
Blown Fuse/ 
Tripped Breaker 
  Short circuit along the power wires  
  Replace Fuse 
  Excessive circuit load 
  Reset Breaker 
Device does not 
power up 
  No power 
  Check for power on power outlet 
  Loose power cord 
  Check power cord 
  Blown Fuse 
  Replace Fuse 
  Reset Breaker 
  Reset Breaker 
Fixture is not 
responding to 
DMX 
  Wrong DMX addressing 
  Check Control Panel and unit 
addressing  
  Damaged DMX cables 
  Check DMX cables 
  Wrong polarity settings on the controller 
  Check polarity switch settings on the 
controller 
  Loose DMX cables 
  Check cable connections 
  Faulty DMX interface 
  Replace DMX input 
  Faulty Main PCB 
  Replace Main PCB 
Loss of signal 
  Bouncing signals 
  Install terminator as suggested 
  Long cable / Low level signal 
  Install amplifier right after fixture with 
strong signal 
  Interference from AC wires 
  Keep DMX cables separated from 
power cables or black lights 
 