CMA Dishmachines CMA-180UC Manual Do Utilizador

Página de 25
Operation  
3.6. Troubleshooting 
 
PROBLEM LIKELY 
CAUSE 
SOLUTION 
Power off at circuit breaker 
Reset circuit breaker 
Machine inoperative 
Defective power switch 
Replace power switch 
P/N: 15521.50
Door is open 
Close door 
Control panel is pulled out 
Secure control panel 
Defective reed switch 
Replace reed switch 
P/N: 00557.55
Defective timer assembly 
Replace timer assembly* 
P/N: 14408.80
Defective pump motor contactor 
Replace contactor 
P/N: 15504.00
Motor inoperative 
Defective motor 
Replace motor 
P/N: 00201.66
Defective reed switch 
Replace reed switch 
P/N: 00557.55
Motor runs with door open 
Defective pump motor contactor 
Replace contactor 
P/N: 15504.00
High limit switch opened or 
defective 
Reset or replace switch 
P/N: 17523.51
Defective thermostat 
Replace thermostat 
P/N: 13417.89
Defective heater contactor 
Replace heater contactor 
P/N: 15504.50
Heater (no heat) 
Defective heater 
Replace heater 
P/N: 15517.00
Defective thermostat 
Replace thermostat 
P/N: 13417.89
Heater (never turns off) 
Defective heater contactor 
Replace heater contactor 
P/N: 15504.50
*The timer assembly motor (
P/N: 00501.00
) or micro switches (
P/N: 00411.00
) can be replaced 
independently if that’s the only component that’s failed. 
MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13 
Page 
15