PLANNiNG iNFORMATiON
PRO hARMONY RANGES
VENTiLATiON REQuiREMENTS
We strongly recommend that a Thermador Professional Wall or Island Hood or 
Custom Insert be installed with all Thermador Pro Harmony Ranges. Downdraft 
ventilation should not be used. Do not install a microwave-hood combination 
above the cooktop, as these types of units do not provide the proper 
ventilation and are not suitable for use with Thermador Pro Harmony Ranges. 
For high output gas cooktops (60,000 BTu or greater), the minimum of one 
(1) CFM of ventilation per 100 BTu is recommended. If the cooktop has a grill 
or griddle, add 200 CFM to the estimated blower capacity. Additional blower 
capacity may be required for longer duct runs.
The following table indicates the ventilation hood options that are 
recommended for use with Thermador Pro Harmony Ranges. Refer to the 
Ventilation section or www.Thermador.com for a complete selection of 
Professional ventilation options, blowers, and accessories.
iMPORTANT VENTiLATiON NOTES:
•  Due to the high surface temperature output of the Pro Harmony Ranges, 
the HPWB Professional Series Wall Hoods or the Professional Series Custom 
Inserts are recommended ventilation solution for these ranges. The PH 
Professional Series Wall Hoods are also a viable option, however the 27" 
depth of the PH Series may not be suitable to all applications.
•  For wall installations, the hood width must, at a minimum, equal the  
nominal width of the appliance cooking surface. Where space permits,  
a hood larger in width than the cooking surface may be desirable for 
improved ventilation performance.
•  For island installations, the hood width should, at a minimum, overhang the 
appliance cooking surface by 3" on each side. 
•  Due to the high heat capability of these cooktops, particular attention 
should be paid to the hood and duct work installation to assure it meets 
local building codes. 
•  For best smoke elimination, the lower edge of the hood should be installed 
30"– 36" above the appliance cooking surface. 
•  If the hood contains any combustible materials (i.e., a wood covering), it 
must be 40"or greater distance above the cooking surface.
ELEcTRicAL AND GAS LOcATiONS
Typical placement of the electrical and gas supply  
can be found within the “Cutout and Range 
Dimensions” located on the product pages. Alternate 
placement within the supply zone is acceptable.  
Dual-Fuel ranges may be connected to the power 
supply with a range supply cord kit (sold separately)  
or by hard-wiring to the power supply. All-Gas 
ranges may be connected to the power supply with 
the supplied range cord or by hard-wiring. It is the 
responsibility of the installer to provide the proper 
wiring components (cord or conduit and wires) and 
complete the electrical connection as dictated by local 
codes and ordinances and/or the National Electric 
Code. The units must be properly grounded.
Installation of the range must be planned so that the 
rough-in of the junction box for the receptacle or 
conduit connection will allow maximum clearance to  
the rear of the unit.
WARRANTY
Limited warranty parts and labor (1 year) 
See page 294 for additional warranty details. 
WiDTh cONFiGuRATiON
VENTiLATiON OPTiONS
30"
4  Burners
30" or 36" Pro Wall Hood 
30" or 36" Custom Insert  
w/optional blower 
42" Island Hood w/optional blower
36"
4  Burners w/Grill or 
Griddle
6 Burners
36" or 42" Pro Wall Hood 
36" Custom Insert w/optional blower 
42" or 48" Island Hood w/optional 
blower
48"
6  Burners w/Grill or 
Griddle
48" or 54" Pro Wall Hood 
48" Custom Insert w/optional blower 
54" Island Hood w/optional blower
Thermador Pro Grand
® Ranges are CGA, CSA and 
AGA approved.
IG
S N
E
D
C
D
E
E
R
I
T IF
Warning: All ranges can tip, 
causing injury. Install anti-tip 
device packed with range.