PP989DN
GE Profile
™
30" Downdraft Electric Cooktop
Specification Created 7/08
220977
Wall Installation: Wall installations
require 25” countertop depth. When
cabinet is flush against the wall, the
fan housing can be rotated to the
horizontal position for direct venting
require 25” countertop depth. When
cabinet is flush against the wall, the
fan housing can be rotated to the
horizontal position for direct venting
through rear wall. Make a countertop cutout in the range
cabinet according to unit dimensions and installation type.
Duct hole is positioned in back of cabinet for through-the-
wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/islands a
minimum 26” countertop depth is suggested. Blower should
be in vertical position. Island or peninsula cabinets may
require adjustment in cutout depth and/or location within
the width dimensions. Duct hole is positioned in bottom of
cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation and
rear wall ducting,
cabinet according to unit dimensions and installation type.
Duct hole is positioned in back of cabinet for through-the-
wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/islands a
minimum 26” countertop depth is suggested. Blower should
be in vertical position. Island or peninsula cabinets may
require adjustment in cutout depth and/or location within
the width dimensions. Duct hole is positioned in bottom of
cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation and
rear wall ducting,
6” PVC duct or locally approved piping
should be used if installing under a poured concrete slab.
Receptacle Location: Install an approved junction box
within shaded area shown in diagram. Junction box must
be at least 10-1/2" below top of cabinet.
Installation Information: Before installing, consult installation
instructions, packed with product, for current dimensional
data.
Receptacle Location: Install an approved junction box
within shaded area shown in diagram. Junction box must
be at least 10-1/2" below top of cabinet.
Installation Information: Before installing, consult installation
instructions, packed with product, for current dimensional
data.
Note: Electrical cable is not supplied with unit.
These cooktops are approved for indoor use only.
KW Rating
240V
9.1
208V
6.9
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 6" minimum spacing to adjacent side wall is required
20
9
4
10-1/2
16
C
L
Cabinet Dimensions (in inches)
*Note: A 6" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
22
7
⁄
16
ʺ
(22
9
⁄
16
ʺ SS)
20
1
⁄
2
ʺ
22ʺ
29
7
⁄
8
ʺ
(30ʺ SS)
2
3
⁄
16
ʺ
(2
1
⁄
4
ʺ SS)
28
3
⁄
4
ʺ